Pitch
offset
: the mounting plate pitch inclination, offset from horizontal. The roll is related to the FiX1
hardware (see Figure 72)
•
Mounting
plate
orientation:
determines whether the FiX1 is mounted hanging down or upright.
For most applications the FiX1 is installed hanging down. In this case the
Mounting plate
orientation
switch should read
Base plate
up
. If the FiX1 is installed upright, the switch should read
Mounting plate
down.
11.6 Surfacing
In order to compute a volume, each scan is smoothed and filtered, then a top surface is generated. This top surface
is compared to a base surface, uploaded by the user, which defines the floor level. The
Surfacing
section deals
with establishing these surfaces and the boundaries of the volume computations.
Figure 73 Mounting plate up (left), mounting plate down (right)