background image

 

 
 
 

 

This document contains confidential and proprietary information that remains the property of Carlson Software Inc. 

 

Page 1 of 2                                                                                           

                     Updated 12/13/2012 

Carlson Software Inc

Carlson Software Inc

Carlson Software Inc

Carlson Software Inc....    

102 West 2

nd

 Street 

Maysville, KY 41056 

www.carlsonsw.com

www.carlsonsw.com

www.carlsonsw.com

www.carlsonsw.com    

Phone: (606) 564-5028 

Fax: (606) 564-6422 

 

Data Collector connection to Parani SD1000 

1)

   

Connect the Parani SD1000 to the standard RS232 9-pin connector of your total station.       

2)  Power on the total station, level it up and configure it for cable communication. 

3)  Set the Dip Switches on the Parani SD1000 to match 
the Baud Rate of your Total Station instrument using 
the table to the right 

 

 

 

 

4)  Attach an antenna to the Parani SD1000 radio before 

powering it on.  Power on the 

RS232 radio

 using the switch 

on the side 

 

    

SD1000 RS232 Radio with Extended Battery 

If the RS232 radio won’t power on and the extended battery was shipped separately you will need to 

remove the back plate and attach the Extended Battery using the 2 screws that are included.  

5)  Use a small pin to press the 

Reset 

button until the MODE light is solid Green to clear out any 

previously configured pairing. 

6)

  

Press the 

Pairing

 button for two seconds until the Mode LED blinks 3 times every 2 seconds.  This puts 

the radio in discoverable mode.  Keep the power on.   

7)

  

Launch SurvCE

 on the data collector then tap the Equip tab and tap “Total station” 

8)  Set the appropriate Manufacturer and Model for your instrument then tap the Comms tab 

9) Set it to Type: Bluetooth, and select the correct BT Type for your data collector.   

10)

    

Tap the “wrenches” icon to the right of BT Type, then tap “Find Device”. 

Reviews: