Owner’s Manual | Model A704-5 Aviation Lighting System
29
© 2008 Carmanah Technologies Corporation
Last revised: April 2008
Complete the following steps to add a light to an airfield with an existing UCS configuration:
1. If not already in Administrator Mode, place the controller into Administrator Mode see section
5.4.2
Administrator Mode
.
2. Enter Transmit UCS Mode (9, ENTER, see section
5.8.3 Unique Code Sequence (UCS)
Management
)
3. Press the push button on the A704-5 light(s)
4. Transmit the UCS by pressing the ENTER button on the wireless controller.
The A704-5 light(s) will flash for five seconds to indicate acceptance of the UCS.
5. When the additional lights have been added, press the CLEAR button on the wireless controller to
exit Transmit UCS Mode.
This operation works for all lights (both non-UCS and UCS).
A704-5 lights previously initialized with the same UCS will also flash in response to the
UCS transmission in Step 4
Creating a new UCS Re-keying
Re-keying allows a new UCS to be transmitted to all lights that have been initialized with the wireless
controller. Carry out the following steps to re-key a light or group of lights:
1. If not already in Administrator Mode, place the controller into Administrator Mode (section
5.4.2
Administrator Mode
).
2. Generate a new UCS (7, ENTER, see section
5.8.3 Unique Code Sequence (UCS) Management
)
3. Enter Transmit UCS Mode (9, ENTER, see section
5.8.3 Unique Code Sequence (UCS)
Management
)
4. Transmit the UCS by pressing the ENTER button on the wireless controller, see section
5.8.3 Unique
Code Sequence (UCS) Management
.
The A704-5 light(s) will flash for five seconds to indicate that it received and accepted the new
UCS.
5. When all lights have been re-keyed press the CLEAR button on the wireless controller to exit
Transmit UCS Mode.
Re-keying only works for lights in which UCS has been initialized.
Removal
Removal disables the UCS in the wireless controller and A704-5 lights. Perform the following steps to
remove the UCS from an airfield:
1. If not already in Administrator Mode, place the controller into Administrator Mode (see section
5.4.2
Administrator Mode
).
2. Remove the UCS (0, Enter, see section
5.8.3 Unique Code Sequence (UCS) Management
)
3. Enter Transmit UCS Mode (9, Enter, see section
5.8.3 Unique Code Sequence (UCS) Management
)
4. Press the pushbutton on the A704-5 light(s)
5. Transmit the UCS removal command by pressing the ENTER button on the wireless controller, see
section
5.8.3 Unique Code Sequence (UCS) Management
The A704-5 light(s) will flash for five seconds to indicate that it received and accepted the remove
UCS command.