6. When the UCS has been removed from all lights, press the CLEAR button on the wireless controller
to exit Transmit UCS Mode.
If some lights do not receive broadcasted UCS, they can be programmed individually
by following the instructions within the section Adding a Light to a UCS System, above.
Copying the UCS to another Controller Reception
Reception allows a controller to receive a UCS from another controller. This allows two or more
controllers to be configured for identical UCS, allowing them to be used for backup, emergency or loss of
the primary controller. To transmit the UCS to another controller the following steps are performed:
In the steps below, controller A refers to the controller transmitting the UCS, and
controller B refers to the controller receiving the UCS.
1. If not already in Administrator Mode, place both controllers into Administrator Mode (see section
5.4.2
Administrator Mode
).
2. Enter Receive UCS Mode on controller B (8, ENTER, see section
5.8.3 Unique Code Sequence
(UCS) Management
Unique Code Sequence (UCS) Management).
3. Enter Transmit UCS Mode on controller A (9, ENTER, see section
5.8.3 Unique Code Sequence
(UCS) Management
Unique Code Sequence (UCS) Management).
The ENTER LED on controller B will light briefly to indicate the UCS was received; controller B
will then exit Receive UCS Mode and return to Administrator Mode.
4. Press the CLEAR button on controller 1 to exit the Transmit UCS Mode.
The controllers are now programmed with the same UCS, and either can be used to control lights
configured with that UCS.
5.10 ARCAL Mode
The Aircraft Radio Control of Aerodrome Lighting (ARCAL) feature works in conjunction with an ARCAL
VHF receiver to allow aircraft pilots to control the airfield lights. For more information about this feature,
contact your Carmanah representative.
Enabling ARCAL:
1. Place the controller into Administrator Mode
2. Press ARCAL (The ARCAL LED starts flashing)
3. Press ENTER (The ARCAL LED is on)
The controller is now in ARCAL Mode.
Disabling ARCAL:
1. Place the controller into Administrator Mode
2. Press ARCAL (The ARCAL LED starts flashing)
3. Press ENTER (The ARCAL LED is off)
4. ARCAL is disabled and the controller is ready for the User or Administrator PIN to be entered.