GP-HS1500
___________________________________________________________
6
g.
Frequency:
Typical North American setting is 60 Hz. Set dip switch S4 to “0” for 50
Hz and “1” for 60 Hz.
h.
Power Save:
Puts inverter to sleep until a load is present. Adjustable by the dip
switches: S1, S2 and S3 on the front panel
3.1.2 Rearview
Operation of the inverter without a proper ground connection may
result in an electrical safety hazard.
a.
Ventilation Port:
Do not obstruct, allow at least one inch for airflow.
b.
Hardwire Remote Port:
Allows the customer to use any 2 wire switch to turn the inverter ON and
OFF. Ex. Toggle switch or light switch.
c
Remote Port:
Compatible with
GP-SWR-B
and
GP-SWR-A
remote controllers:
Before using the remote, ensure the inverter’s main switch is in the
REMOTE position and the input voltage is the same as the remote.
d.
Chassis Ground:
Ground to vehicle chassis using # 8 AWG wire.
e.
Battery Terminals:
[+] is positive and [-] is negative.
Connect your 12V battery or other 12V power source to your 12 volt
inverter. If your inverter is a 24V model, connect only a 24V battery or
other 24V power source. Reverse polarity connection will blow the internal
fuse and may damage inverter permanently.