background image

PLUMBERS INSTALLATION INSTRUCTIONS - TRIM KIT (98451C6A)

WATER EFFICIENT - CONNECTED TAPWARE ENABLED BY AWARE

ELECTRONIC WALL MOUNTED TAP

IS1682C(08/18)

Sheet 2 of 2

1)

6)

2)

3)

4)

5)

7)
8)
9)

Remove mounting box cover: Using a 6mm allen key, remove cover retaining screws (6)

and cover (5). Ensure that isolation valve is still in the closed position.

Remove solenoid blanking plug and attach solenoid (1). Note: Lightly tighten

only (1 Nm). Open the isolation valve and check for leaks.

Align & attach outlet spout assembly (2) to outlet spigot (3) with retaining

nut (4), ensuring cables do not become jammed or damaged.
Connect Cables: 

(Green + Yellow) to solenoid

(Brown + White) to blue module

Power supply cable to blue module.

Secure cables using the integrated retaining features.
Slide backing plate (5) over spout assembly and attach to mounting box by

re-using the 4 off plastic cover retaining screws (6). 

DO NOT OVERTIGHTEN.

Note: Backing plate has integrated gasket to seal against the tile surface.
Slide fascia plate (7) over spout and attach to backing plate. The fascia plate

is attached by lifting slightly (approx 2mm) to allow the mounting tags to 

engage. Drop the plate and press down lightly to engage with backing plate.

Slide the rubber seal (8) over the spout and press into facsia plate firmly.
Slide cover ring (9) and push firmly against the fascia plate. 

Secure grub screw with 2mm allen key underneath.

Installation

10)

Commisioning Procedure:

a) Power on the device at the GPO and allow the unit to

    complete the calibration sequence as follows:

       1) The indicator LED will flash, then allow a small amount of

            water to flow to wet surfaces under sensor.

       2) The unit will then perform another calibration on the wet surface

           and flush again.

       3) The indicator LED will then flash for 30 seconds and then stop. 

       4) The unit is now ready to operate.

b) Test operation by placing hands under the sensor (within 100mm from Spout).

     Water should flow within 0.5 seconds.

     Remove hand and the water supply should stop within 2 seconds.

IMPORTANT: Please refer to AWARE operation manual (IS 1683) to configure

wireless communication and change the  device default settings.

1

3

4

5

6

7

8

9

TM

Fig. 4

2

IMPORTANT

It is the installers responsibility to ensure the
installation complies with AS/NZS3500.1, 
AS/NZS3500.2, AS/NZS3500.4.1, AS/NZS3500.4.2
and local water authority regulations.

Refer to side 1 of this instruction for in-wall body installation.

Important Information

Not suitable for gravity feed systems.

*

*

All pipework must be thoroughly flushed prior to installation, as foreign materials

may block the flow regulating device and reduce the flow of water. Note: Aerator

insert must be retightened to prevent removal by hand.

*

Wall outlet is fitted with a flow regulated aerator insert. This low flow rate may not be

suitable for connection to some Instantaneous Gas Water Heaters, some Tempering

Valves, some Solar Water Heaters & some Thermostatic Mixing Valves. 

Check with the manufacturers of these products.