When battery terminals are reverse connected, the fuse will blow to protect appliances.
Overheat Protection
When the heat sink temperature exceeds 45°C, the inner cooling fan will switch on automatically to cool the inverter.
When the internal temperature exceeds 70°C, the AC output will shut off automatically and the ALARM/WARNING light will turn red. The unit
will be unusable for 15 minutes.
6. TROUBLESHOOTING REFERENCE
Acoustic buzzer alarms
When using the inverter with acoustic devices, some inferior acoustic devices will buzz, as the output wave from the inverter is a modified
sine wave inverter.
TV Interference
You can reduce interference to a minimum by using a filter. On occasions when the interference of weak signals becomes too obvious, you
can try the following:
• Place the inverter some distance away from the TV and TV antenna.
• Try to change the direction of the TV signal cable and TV antenna to reduce interference to a minimum.
• Use a high-quality screen cable antenna.
Problem: No output voltage
POSSIBLE CAUSES
SOLUTION
Battery voltage too low
Recharge or replace the battery
Overload
Reduce the load
Inverter thermal protection
Cool the inverter and position it in a well-ventilated area; Reduce the load
Inverter start-up fail
Try starting the inverter again
Reverse polarity connection and fuse melted
Replace the fuse with a fuse of equivalent value
Problem.· Inverter no response
POSSIBLE CAUSES
SOLUTION
Poor contact between battery and inverter
Reconnect the battery and inverter
Reverse polarity connection and fuse melted
Replace the fuse with a fuse of equivalent value
Problem.· Output voltage low
POSSIBLE CAUSES
SOLUTION
Input voltage too low
Make sure the input voltage is within the rated range.
Overload
Reduce the load
Problem.· Low voltage alarm
POSSIBLE CAUSES
SOLUTION
Battery no power
Recharge the battery
Battery voltage too low or poor connection
Recharge the battery, check terminal connections or clean terminal with a dry cloth
7 SPECIFICATIONS
ITEMS
MODEL
0510350
0510351
0510352
0510353
0510354
Continuous power
150W
300W
600W
IOOOW
1500W
Surge Power
300W
600W
1200W
2000W
3000W
Dimensions (L x W x H)
120 x 100 x 50
120 x 100 x 50
150 x 100 x 55
210 x 150 x 70
310 x 150 x 70
Packing
PCS/CTN
16
16
16
6
4
KGS/CTN
14.8
15.0
19.0
15.4
12.6
MEAS (L x W x H) cm
44 x 38 x 34
44 x 38 x 34
44 x 38 x 34
42 x 34 x 45
44 x 42 x 33
0510350-62i_A5.indd 5
0510350-62i_A5.indd 5
08-07-2020 08:10
08-07-2020 08:10