Remark
After installing panel,pull in the panels to the
front frame side as ③
When installing panel,please be noted
as below.
Sort the panel equally
front frame
front frame
gutter
Attach the panel
to the end.
side frame
roof rafter
A−A' cross-section
・Peel off the curing sheet.
・Insert the panel into the front frame and then into
the gutter.
Installation of Roof Retainer
(depth set)
(depth set)
Remark
・If the screw of installing the roof retainer
(middle part)is tighten too much,the screw
will run idle.
(tightening torque less than15kgf.cm)
・If the screw head leans when installing the roof
retainer,it will cause water leakage(water will
enter from the screw head clearance),
So install it not to make clearance.
Insert the end roof retainer into the front frame
side and see the U-shaped gutter of the side
frame and fix from the front frame side.
Do sealing work at the insert part of the
roof retainer(end part).
Insert the roof retainer into the front
frame and fix from the front frame side.
Insert until it touches the
roof panel cushion of the
front frame
step1
step1
step2
step2
step3
step3
drilling screw
drilling screw
drilling screw
roof retainer
roof retainer
roof retainer
end roof retainer
end roof retainer
roof retainer
side frame
(top)
(bottom)
side frame
small truss screw
(with washer)
small truss screw
(with washer)
sealing
U shaped
gutter
gutter
Installation Drawing
12
Summary of Contents for KDR Series