Access Navigator - Release 1.8
August 2003
14-5
Alarm Clearing
Clear Alarms – FDL
Table 14-3 CLI Minor Alarm Message and Trouble Clearing Procedure
Event Message
Description
Trouble Clearing Procedure
-48V DC power
A/B
Low or Missing
-48V DC power supply to the
controller (A or B) is low or
missing. Under normal condition
power is shared between controller
cards.
Check power cable connection or
battery voltage of the reporting
controller card.
Alarm Input
1/2/3
Detected
Contact closure was detected on
the indicated alarm input (1,2, or
3). Alarm inputs can be wired to
the facility alarm system. Under
normal conditions the facility
alarm system should provide open
contacts to the alarm inputs.
Providing contact closure to an
alarm input results in this alarm.
The alarm is cleared when the
contact is opened.
Controller
A/B
Incompatible
Controllers do not support the
same functionality; for example,
one supports EOC/TMC and the
other does not.
Remove the standby controller and
replace with a compatible
controller (see
Replace Controller
Card
on
page 16-3
or update
controller with compatible
software (see
Update Controller
Card Software
on
page 17-1
).
Controller
A/B
Removed
Upon removal the controller card
(A or B), the remaining controller
card is now
active
.
Insert a good controller card into
the empty slot
Controller A/B software
version mismatch
Controller card software versions
do not match.
Update offending controller with
appropriate software (see
Update
Controller Card Software
on
page 17-1
).
DS1
n
Major Line CV
DS1 is receiving Line Code
Violations at a rate greater than
1.0 x 10-3. This indicates a weak
signal or faulty wiring.
Correct the problem with the
incoming DS1 signal, or use
following command to provision
the DS1 as out of service:
set ds1
<n> <up|down>
Summary of Contents for Access Navigator
Page 1: ...Access Navigator USER MANUAL Part Number 770 0079 AP Product Release 1 8 August 2003 ...
Page 170: ...6 66 August 2003 Access Navigator Release 1 8 Electrical Installation Exit Management Session ...
Page 214: ...9 20 August 2003 Access Navigator Release 1 8 Provision DCS Service Test DS1 and DS0 Circuits ...
Page 342: ...14 22 August 2003 Access Navigator Release 1 8 Alarm Clearing Ethernet Link Status LED ...
Page 634: ...18 178 August 2003 Access Navigator Release 1 8 CLI Language Reference CLI Command List ...
Page 658: ...B 6 August 2003 Access Navigator Release 1 8 FDL Interface Access Bank II Capabilities ...
Page 668: ...C 10 August 2003 Access Navigator Release 1 8 SNMP Interface SNMP Trap Reports ...
Page 682: ...GlossaryGlossaryGlossaryGlossary 14 August 2003 Access Navigator Release 1 8 Glossary ...
Page 704: ...Index 1 22 August 2003 Access Navigator Release 1 8 Index ...