Axxius 800 - Release 2.2
5-17
CLI Commands
add
add (router-lan) filter protocol
Use the add (router-lan) filter protocol command to add a protocol filter to the table of
Layer 2 filters applied to the specified LAN interface. Note that you only need to identify
either an Ethernet or IEEE value, but not both. The other should be entered as 0.
Syntax:
add {rtr_lan-addr} filter protocol {ether-type}
{ieee-value} {"filter-name"}
Example:
add 2:1 filter protocol 0x0807 0x0 "XNSrule"
The example will add a custom layer-2 filter that will match all XNS packets.
{rtr_lan-addr}
The Router address is in the form {slot:port} or {slot "profile-name"}.
{ether-type}
This assigned Ethernet value for this protocol. The ether-type is entered as a 16-bit
hexadecimal value. See Ethernet Protocol Types on page D-6 for protocol number and
descriptions.
{ieee-value}
The assigned IEEE value for this protocol. The IEEE value is the same as the SDAP and
SSAP values in a SNAP packet. The match value is entered as a 8-bit hexadecimal value.
{"filter-name"}
A symbolic name given to identify a filter rule. This name must be enclosed in quotes, with
a maximum of 8 characters.
slot
Slot number (1-8) that contains the Router card.
port
Port number of the Router.
"profile-name"
The profile name for the Router interface. Name must be enclosed in
quotes, with a maximum length of 11 characters.
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...