Axxius 800 - Release 2.2
5-83
CLI Commands
set
set (ds3)
Use the set (ds3) command to set up DS3 interfaces. The command specifies a range of
interfaces and the setting to apply.
Syntax:
set {ds3-addr} {setting}
Example:
set a:1 framing m23
To set DS3 1 (port 1) on a DS3 Controller (slot A) to use M23 framing.
{ds3-addr}
DS3 address in the form {slot:port}.
{setting}
slot
A for the controller card, or 1-8 for service cards.
port
Port number, range or all.
down
Set the DS3 as Out-of-Service
up
Set the DS3 as In-Service. Enables alarm reporting (and LED) for the
port specified
berthreshold
Set Bit Error Rate protection switchover threshold.
{value}
4-8 for 10e-4 to 10e-8
clock
Set the transmit clock source
loop
Set to clock recovered from the DS3 receive
normal
Set to master transmit clock source
dejitter
Turn the De-jitter buffer on or off
off
De-jitter buffer off
on
De-jitter buffer on
equipment
Set equipment loopback on the DS3 or PMDL (Path Maintenance Data
Link) ID
id
Set the DS3 equipment PMDL ID string
Command syntax: set {ds3-addr} equipment id
{"string"}
{"string"} = transmission vendor’s identification, up to
30 characters, enclosed in quotes.
loopdown
Disable equipment loopback on the DS3
loopup
Enable equipment loopback on the DS3
facility id
Set the DS3 facility PMDL ID string
Command syntax: set {ds3-addr} facility id {"string"}
{"string"} = transmission vendor’s identification, up to 38 characters,
enclosed in quotes.
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...