Axxius 800 - Release 2.2
14-5
Quad T1 & Quad DS1/E1 Card
Technical Specifications
Clocking
l
Loop-timed from any T1
l
External from BITS clock input (t1.101, t1.102 signal type)
l
Revertive or non-revertive (provisionable clock switching provides automatic
backup to secondary T1 should the primary T1 fail
l
Operates as a Stratum 4E device as defined by Telcordia GR-1244-CORE and
AT&T TR 62411
Alarms
l
Support standard T1.403 alarms
l
LOS (Loss of Signal), Red, Yellow, Blue
l
ESF Performance Error Count Threshold
l
Timing Loss
l
All alarms are logged in an event log
l
Loss of power triggers minor alarm
l
Generates SNMP traps for alarming
Testing and Diagnostics
l
T1.403 payload loopbacks (ESF only)
l
T1.403 remote and local line loopbacks (ESF and SF)
l
T1.231 Performance History (15 minute intervals, 24 hour totals)
l
T1.403 Performance Report Messages (PRMs)
Power Consumption
l
Less than 4.5 W per card
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...