Axxius 800 - Release 2.2
18-3
Maintenance
Software Loading
Loading Router Software via TFTP
1. Login to the Axxius 800, using a terminal emulation program or via Telnet.
2. Enter:
load [rtr_card-addr] tftp {ip-addr} "file-name"
The tftp utility provided by Carrier Access with the downloadble software
must also be running, in the same directory as the software file.
3. After download, the program will be loaded from RAM into the flash memory
and the system will automatically restart. Wait until the boot menu prompt is
displayed before powering down the unit. If the download fails and no prompt
is seen after a full minute, cycle power and repeat the process.
4. Re-establish communication with the CLI using a terminal emulation program
or Telnet. Check all configurations and system operation.
Command
Description
load {rtr_card-addr} tftp
{ip-addr} "file-name"
CLI command to load software to the Standby
Controller. See the load tftp command for
details.
reset standby
Do you really want to do
this ? Y
Reset the Standby Controller. You will be asked
to confirm this command, answer Y (Yes). See
reset (controller) command for details.
status equipment
Check the Standby Controller status, when it
displays hot standby go on to the next step. If hot
standby does not display stop here. If you go
further you may affect service. Start the
process again and if you are not successful call
Customer Service. See status equipment
command for more details.
switch controller
Set the signal clock switching. See the set clock
command for details.
You will be disconnected from the unit when switching Controllers. Re-establish connection
with Axxius.
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...