3-10
Axxius 800 - Release 2.2
Electrical Installation and Cabling
Chassis Connections
Visible and Audible Alarms
The external alarm connectors are six-pin connectors with two output pairs for each
alarm level (pins 1 & 2 for minor, pins 3 & 4 for major and 5 & 6 for critical alarms).
1. Strip wire so that approximately 5/16 of bare wire is exposed.
2. Insert wire into opening and tighten screw to clamp wire.
3. Ensure that no bare wire shows after the wires are installed.
4. Plug connector in the AUDIBLE ALARMS or VISIBLE ALARMS connector,
as seen in the graphic above and secure with set screws.
Audible Alarm
Visible Alarm
Tighten screw
to clamp wire
Set screw
Wire
back of Axxius
Connectors plugged into Axxius
pin 1