2-7
Table 2-1. Electrical Control Positions --- BELOW ---10
_
C (+14
_
F) or ---5
_
C (+23
_
F) optionally
CONTROL CIRCUIT
COOLING
HOLDING ZONE **Dehumidification
HEATING
DEFROST
Compressor Contactor (C)
Energized
De-energized
**
**
De-energized
Condenser Fan Motor
Contactor (CF)
Energized
De-energized
**
**
De-energized
Single
Speed Evaporator Motor
Relay (EF)
Energized
Energized
**
**
De-energized
High
Speed Evaporator
Motor Relay (EF)
De-energized
De-energized
Refer to section
1.12.4.a.2
Refer to section
1.12.4.a.2
De-energized
Low
Speed Evaporator
Motor Relay (ES)
Energized
Energized
Refer to section
1.12.4.a.2
Refer to section
1.12.4.a.2
De-energized
Defrost Relay (DR)
De-energized
De-energized
**
**
Energized
Heater Relay (HR)
De-energized
De-energized
**
**
Energized
INDICATING LIGHTS
Cool
ON
OFF
**
**
OFF
Defrost
OFF
OFF
**
**
ON
In-Range
On -- If In-Range (Refer to paragraph 1.12.5, Code 30)
Heat
OFF
OFF
**
**
ON
POWER CIRCUIT
Compressor
Energized
De-energized
**
**
De-energized
Condenser Fan Motor
Energized
De-energized
**
**
De-energized
Heaters
De-energized
De-energized
**
**
Energized
Evaporator Fan Motors
Energized
Energized
**
**
De-energized
*
Unit with optional Humidity sensor
** Dehumidification and heating modes do not operate at set points below --10
_
C (14
_
F) or the optional setting of --5
_
C (23
_
F)
Table 2-2. Electrical Control Positions --- ABOVE ---10
_
C (+14
_
F) or ---5
_
C (+23
_
F) optionally
CONTROL CIRCUIT
COOLING
HOLDING ZONE
* Dehumidification
HEATING
DEFROST
Compressor Contactor (C)
Energized
De-energized
Energized
De-energized
De-energized
Condenser Fan Motor
Contactor (CF)
Energized
De-energized
Energized
De-energized
De-energized
Single
Speed Evaporator
Motor Relay (EF)
Energized
Energized
Energized
Energized
De-energized
High
Speed Evaporator
Motor Relay (EF)
Energized
Energized
Refer to section
1.12.4.a.2
Refer to section
1.12.4.a.2
De-energized
Low
Speed Evaporator
Motor Relay (ES)
De-energized
De-energized
Refer to section
1.12.4.a.2
Refer to section
1.12.4.a.2
De-energized
Defrost Relay (DR)
De-energized
De-energized
De-energized
De-energized
Energized
Heater Relay (HR)
De-energized
De-energized
Energized
Energized
Energized
INDICATING LIGHTS
Cool
ON
OFF
ON
OFF
OFF
Defrost
OFF
OFF
OFF
OFF
ON
In-Range
On -- If In-Range (Refer to paragraph 1.12.5, Code 30)
Heat
OFF
OFF
ON
ON
ON
POWER CIRCUIT
Compressor
Energized
De-energized
Energized
De-energized
De-energized
Condenser Fan Motor
Energized
De-energized
Energized
De-energized
De-energized
Heaters
De-energized
De-energized
Energized
Energized
Energized
Evaporator Fan Motors
Energized
Energized
Energized
Energized
De-energized
Downloaded from