DESCRIPTION
2.1 GENERAL DESCRIPTION
2.1.1 Refrigeration Unit -- Front Section
The unit is designed so that the majority of the
components are accessible from the front, see
Figure 2-1. The upper access panels allow entry into the
evaporator section, and the center access panel allows
access to the evaporator expansion valve, quench
expansion valve, suction modulation valve and
evaporator coil heaters. The unit model number, serial
number and parts identification number can be found on
the serial plate to the left of the economizer.
2.1.2 Fresh Air Makeup Vent
The function of the upper or lower makeup air vent is to
provide ventilation for commodities that require fresh air
circulation.
1
2
3
8
4
13
5
14
17
9
18
16
12
15
10
11
6
7
1. Access Panel (Evap. Fan #1)
2. Access Panel (Heaters, Suction Modulating
Valve, Quench Expansion Valve & Evaporator
Expansion Valve)
3. Fork Lift Pockets
4. Control Box
5. Compressor
6. Receiver or Water Cooled Condenser
7. Economizer
8. Unit Serial Number, Model Number and
Parts Identification Number (PID) Plate
9. Power Cables and Plug
10. Condenser Fan
11. Autotransformer
12. TransFRESH Communications Connector
13. Interrogator Connector (Front left)
14. Temperature Recorder
15. Lower Fresh Air Makeup Vent Location
(Blank Cover Shown)
16. TIR (Transports Internationaux Routiers)
Sealing Provisions - Typical All Panels
17. Upper Fresh Air Makeup Vent
18. Access Panel (Evap. Fan #2)
Figure 2-1 Refrigeration Unit -- Front Section
Downloaded from
Summary of Contents for 69NT40-531 Series
Page 2: ...Downloaded from ManualsNet com search engine ...
Page 4: ...Downloaded from ManualsNet com search engine ...
Page 8: ...Downloaded from ManualsNet com search engine ...
Page 16: ...Downloaded from ManualsNet com search engine ...
Page 57: ...Downloaded from ManualsNet com search engine ...
Page 104: ...Downloaded from ManualsNet com search engine ...
Page 106: ...7 2 T 292 Figure 7 2 SCHEMATIC DIAGRAM Downloaded from ManualsNet com search engine ...