T-292
2-7
2.2 REFRIGERATION SYSTEM DATA
Model
RSH105
Weight (Dry)
46.5 kg (103 lb)
a Compressor/Motor
Approved Oil
Mobil -- ST32
a. Compressor/Motor
Assembly
Oil Charge
2957 ml (100 ounces)
Assembly
Oil Sight Glass
The oil level range, with the compressor off,
should be between the bottom and one-eighth
level of the sight glass.
b. Evaporator Expansion
Valve Superheat
Verify at --18
_
C
(0
_
F) container box
temperature
4.4 to 6.7
_
C (8 to 12
_
F)
c. Economizer Expansion
Valve Superheat
4.4 to 11.1
_
C (8 to 20
_
F)
d Heater Termination Thermostat
Opens
54 (
¦
3)
_
C = 130 (
¦
5)
_
F
d. Heater Termination Thermostat
Closes
38 (
¦
4)
_
C = 100 (
¦
7)
_
F
e High Pressure Switch
Cutout
25 (
¦
1.0) kg/cm
@
= 350 (
¦
10) psig
e. High Pressure Switch
Cut-In
18 (
¦
0.7) kg/cm
@
= 250 (
¦
10) psig
Unit Configuration
Charge Requirements -- R-134a
Water Cooled
4--Row Coil
5--Row Coil
f. Refrigerant Charge
Water-Cooled
Condenser
5.56 kg
(12.25 lbs)
6.3 kg
(13.75 lbs)
Receiver
5.22kg
(11.5 lbs)
5.9kg
(13 lbs)
g Fusible Plug
Melting point
99
_
C = (210
_
F)
g. Fusible Plug
Torque
6.2 to 6.9 mkg (45 to 50 ft-lbs)
h. Sight Glass/Moisture Indicator
Torque
8.9 to 9.7 mkg (65 to 70 ft-lbs)
i Rupture Disc
Bursts at
35
¦
5% kg/cm
@
= (500
¦
5% psig)
i. Rupture Disc
Torque
6.2 to 6.9 mkg (45 to 50 ft-lbs)
j. Unit Weight
Refer to unit model number plate.
k Water Pressure Switch
Cut-In
0.5
¦
0.2 kg/cm
@
(7
¦
3 psig)
k. Water Pressure Switch
Cutout
1.6
¦
0.4 kg/cm
@
(22
¦
5 psig)
Downloaded from
Summary of Contents for 69NT40-531 Series
Page 2: ...Downloaded from ManualsNet com search engine ...
Page 4: ...Downloaded from ManualsNet com search engine ...
Page 8: ...Downloaded from ManualsNet com search engine ...
Page 16: ...Downloaded from ManualsNet com search engine ...
Page 57: ...Downloaded from ManualsNet com search engine ...
Page 104: ...Downloaded from ManualsNet com search engine ...
Page 106: ...7 2 T 292 Figure 7 2 SCHEMATIC DIAGRAM Downloaded from ManualsNet com search engine ...