3-24
T-292
Table 3-8 DataCORDER Function Code Assignments
NOTE
Inapplicable Functions Display “
-- -- -- -- --
”
To Access: Press ALT. MODE key
Code
No.
TITLE
DESCRIPTION
dC1
Recorder Supply
Temperature
Current reading of the supply recorder sensor.
dC2
Recorder Return
Temperature
Current reading of the return recorder sensor.
dC3-5
USDA 1,2,3 Temper-
atures
Current readings of the three USDA probes.
dC6-13
Network Data
Points 1-8
Current values of the network data points (as configured). Data point 1 (Code
6) is generally the humidity sensor and its value is obtained from the Control-
ler once every minute.
dC14
Cargo Probe 4 Tem-
perature
Current reading of the cargo probe #4.
dC15-19 Future Expansion
These codes are for future expansion, and are not in use at this time.
dC20-24 Temperature Sen-
sors 1-5 Calibration
Current calibration offset values for each of the five probes: supply, return,
USDA #1, #2, and #3. These values are entered via the interrogation pro-
gram.
dC25
Future Expansion
This code is for future expansion, and is not in use at this time.
dC26,27 S/N, Left 4, Right 4
The DataCORDER serial number consists of eight characters. Function code
dC26 contains the first four characters. Function code dC27 contains the last
four characters. (This serial number is the same as the Controller serial num-
ber)
dC28
Minimum Days Left
An approximation of the number of logging days remaining until the Data-
CORDER starts to overwrite the existing data.
dC29
Days Stored
Number of days of data that are currently stored in the DataCORDER.
dC30
Date of last Trip start
The date when a Trip Start was initiated by the user. In addition, if the system
goes without power for seven continuous days or longer, a trip start will auto-
matically be generated on the next AC power up. Press and hold “ENTER”
key for 5 seconds to initiate a “Trip Start”.
dC31
Battery Test
Shows the current status of the optional battery pack.
PASS
: Battery pack is fully charged.
FAIL
: Battery pack voltage is low.
dC32
Time: Hour, Minute
Current time on the real time clock (RTC) in the DataCORDER.
dC33
Date: Month, Day
Current date (month and day) on the RTC in the DataCORDER.
dC34
Date: Year
Current year on the RTC in the DataCORDER.
dC35
Cargo Probe 4
Calibration
Current calibration value for the Cargo Probe. This value is an input via the
interrogation program.
Downloaded from
Summary of Contents for 69NT40-531 Series
Page 2: ...Downloaded from ManualsNet com search engine ...
Page 4: ...Downloaded from ManualsNet com search engine ...
Page 8: ...Downloaded from ManualsNet com search engine ...
Page 16: ...Downloaded from ManualsNet com search engine ...
Page 57: ...Downloaded from ManualsNet com search engine ...
Page 104: ...Downloaded from ManualsNet com search engine ...
Page 106: ...7 2 T 292 Figure 7 2 SCHEMATIC DIAGRAM Downloaded from ManualsNet com search engine ...