24. Once aligned, push the generator to fully seat the torsional dampener into the aluminum housing of the
flywheel adaptor plate.
25. With the torsional dampener seated into the aluminum housing, the alignment bolts (2) can be removed, and
the generator mounting bolts (12) can be reinstalled. Torque to 34 Nm (25 ft-lb). Install several mounting
bolts to secure the generator before removing the alignment bolts. See
NOTE
Although the torsional dampener and mating surface of the generator will generally keep the generator
coupled to the engine, even with all of the bolts removed, it is safest to start installation of the top
generator bolts first, just in case the generator shifts.
Figure 5.9 Generator Mounting Bolts
26. With all of the generator mounting bolts secured, use the lift to raise the generator / engine in order to
remove the support blocks under the engine.
27. Place the generator support plate mounting bolts (2) down into the generator support plate in order to line up
the mounting bolt holes with the shockmounts.
28. Ensure that the large washers placed on the shockmounts and slowly lower the generator / engine so that
the generator support plate holes line up with the shockmount holes.
29. Remove the generator support plate bolts and install the bolts / large washers from the bottom of the
shockmounts through the generator support plate. Secure the bolts (2) with nuts, torque to 102 Nm (75 ft-lb).
30. Tighten the engine shockmount bolts, torque to 122 Nm (90 ft-lb).
31. Replace the lower radiator access panel and secure with bolts / washers (3).
32. Re-secure the battery charger cables to the bottom of the battery charger.
33. Observe proper polarity when installing the battery or connecting a battery charger, the negative battery terminal
must be grounded. Reverse polarity may damage the charging system. When charging the battery in unit, isolate
the battery by disconnecting the negative battery terminal first, then the positive. Once the battery has been
charged, connect the positive battery terminal first, then the negative.
Summary of Contents for 69UG15
Page 2: ......
Page 4: ......
Page 12: ......
Page 32: ......
Page 40: ......
Page 58: ......
Page 60: ...T 375 6 2 Figure 6 2 Schematic for 12 VDC Control Circuit 12 VDC Control Circuit ...
Page 61: ...6 3 T 375 Figure 6 3 Schematic High Voltage Circuitry High Voltage Circuitry Receptacle Box ...
Page 62: ......
Page 65: ......