6.    OPERATION                                                     

CITIMAX  series  are  powered  on  Road  mode  by  the 
vehicle battery (alternator).   
In  this  chapter,  we  will  state  the  operation  principle 
respectively.   

6.1    DIN Operation principle                                                             

For  its  big  volume,  we  should  install  the  DIN  display 
board in the fixed place of the cab cage. 

After starting up, the refrigeration unit by pressing the 

 

key,  unit  start-up  and  shut-down  are 

automatic. 

 

An  open-type  compressor  is  driven  by  the  engine  of 
the vehicle. The vehicle battery (alternator) powers the 
evaporator and condenser fans. The unit automatically 
shuts  down  when  the  engine  is  switched  off  with  the 
ignition key.   
 
The  unit  can  be  completely  shut  down  manually  by 

pressing the 

 

key on the cab command. 

 

Temperature control 

 

As soon as the set-point temperature has been reached, 
temperature  control  is  obtained  by  shut  down  and 
start-up of the electro-magnetic clutch. 

 

Condenser fan is controlled by the microprocessor and 
evaporator  fan(s)  cut  out  during  regulation.  When 
transporting  fragile  loads  such  as  fresh  meat, 
vegetables  and  cheese,  it  is  possible  to  program  the 
microprocessor to obtain continuous ventilation by the 
evaporator during regulation. 
 

Defrost 

  Frozen unit only 

 

Defrost  operation  is  fully  automatic  but  can  be 
manually controlled.   
-  Defrost  cycles  are  fully  controlled  by  the  integrated 
microprocessor.   

 

-  During  the  defrost  cycle,  the  evaporator  fan  shuts 
down.  The  condenser  fan  is  controlled  by  the 
microprocessor. 

 

- Defrost cycle termination is controlled by a timer or 
defrost temperature sensor (DTS). 

 

-  During  the  defrost  cycle,  the  cab  command  display 
indicates "d F". 

 

 

Heating - For frozen unit with heating function 

option 

Heating is provided by hot gas system. 

 

 

The  evaporator  fan  operates,  the  condenser  fan  is 
controlled by the microprocessor

.

 

6.1.1    To start the unit                                                           

 
1. Start the vehicle engine. 

2. Start the unit by pressing the 

  key. Start-up 

is time-delayed for 50 seconds. 
 
3.  The  digital  display  of  the  cab  control  displays  the 
box temperature. 

 

4.  Check  the  temperature  setpoint  is  correct  by 

pressing  the 

  key.  The  setpoint  temperature  is 

highlighted on the digital display. 

 

5.  Enter  a  new  setpoint  if  necessary  (See  To  change 
setpoint temperature– paragraph 6.4) 
 
In the event of difficulty on start-up, check that:                       
- The main road fuse has not blown. If it is ok, contact 
your Carrier Service centre.                                             
-  The  temperature  selected by  the  cab  control  has  not     
been affected.                                                                                                   

                           

                             

 

6.1.2 To stop the unit                                                     

-    For  a  short  stop  (ex.  delivery):  switch  off  by  the 
vehicle ignition key.   

-    For  a  long  stop:  press  the 

  key  in  the  cab 

command. 

6.1.3    To change setpoint temperature               

             

Important                                     

If,  when  settings  are  adjusted,  no  key  is  activated 
within  5  sec.  the  system  reverts  to  displaying  the 
box temperature. All changes made are recorded.     
 

                                                                                                 

If  the  cab  command  is  built  into  the  vehicle  control 
panel,  the  command  unit  must  be  located  as  far  as 
possible 

from 

the 

heating 

ducts. 

Maximum 

temperature of exposure : 85°C.                                       

 

1.  Press  the 

  key  to  display  setpoint 

temperature.   

2.  Press  the 

  or 

  key  to  change  the 

setpoint. 

3.  Press  the 

  key  to  return  to  box  temperature 

display.   

Summary of Contents for CITIMAX 280

Page 1: ...62 69137 00 20180627 1 GB English 3 CN Chinese 17 ...

Page 2: ...62 69137 00 20180627 2 ...

Page 3: ...is guide will help to minimize on the road problems In addition a comprehensive maintenance program will help to insure that the unit continues to operate reliably Such a maintenance program will also help to control operating costs increase the unit s working life and improve performance When having your unit serviced be sure to specify genuine Carrier Transicold replacement parts for the highest...

Page 4: ...you The complete nameplate 1a is fixed on the frame and the additional serial number is fixed on unit side 1b easily readable 1 3 Noise level sticker This sticker indicates the noise level in Lwa sound power level 2 SAFETY This manual contains safety and service instructions to follow in order to prevent any accident Some of following stickers have been placed on the product for your SAFETY BEFORE...

Page 5: ... or guard for example make sure they are in place Never removed them when the refrigeration unit is running Always keep your hands body parts clothes hairs and tools far from moving parts Refrigerant The refrigerant contained in this refrigeration unit can cause frostbite severe burns or blindness in case of projection and direct contact with the skin or eyes In contact with flame or heat refriger...

Page 6: ...ety glasses Respect polarity when connecting a battery CAUTION Under no circumstances should anyone attempt to repair the Logic or Display Boards Should a problem develop with these components contact your nearest Carrier Transicold dealer for replacement Under no circumstances should a technician electrically probe the processor at any point other than the connector terminals where the harness at...

Page 7: ...important to check the temperature of the product being loaded to ensure that it is at the correct temperature for transport The refrigeration unit is designed to maintain the temperature of the product at the temperature at which it was loaded it was not designed to cool a warm product SOME ADVICE Before loading Pre cool the inside of the insulated body by lowering the temperature for about 15 mi...

Page 8: ...ent display boards DIN display board and SMART display board as the following pictures show 3 4 8 5 6 7 9 DIN Display 5 2 4 7 9 10 11 3 6 8 SMART Display 5 1 Cab control description Keep the fold out sheet while reading the instructions This functional accessory simplifies all control operations From your seat you can carry out all the control operations shut down automatic start up adjusting the ...

Page 9: ... by the microprocessor Defrost cycle termination is controlled by a timer or defrost temperature sensor DTS During the defrost cycle the cab command display indicates d F Heating For frozen unit with heating function option Heating is provided by hot gas system The evaporator fan operates the condenser fan is controlled by the microprocessor 6 1 1 To start the unit 1 Start the vehicle engine 2 Sta...

Page 10: ...e display 6 1 6 To change default parameters 1 Press simultaneously the and keys to display minimum setpoint 2 Press the or key to change minimum setpoint 0 C 20 C or 29 C default value 29 C 3 Press the key to display differential parameter 4 Press the or key to adjust the differential value Dif1 1 C Dif2 2 C Dif3 3 C default value Dif2 5 Press the key to display evaporator fan operating mode duri...

Page 11: ...tions 280 350 500 700 con Communication malfunction No Communication line 280 350 400 500 700 Err Programming mistake of the maximum setpoint by user Setpoint lower than minimum setpoint but in the range 29 C 30 C No Setpoint 280 350 400 500 700 6 2 SMART Operation principle For its small volume we can install the SMART display board anywhere of the cab cage After starting up the refrigeration uni...

Page 12: ...ng stop press the key in the cab command 6 2 3 To change setpoint temperature Important If when settings are adjusted no key is activated within 5 sec the system reverts to displaying the box temperature All changes made are recorded If the cab command is built into the vehicle control panel the command unit must be located as far as possible from the heating ducts Maximum temperature of exposure ...

Page 13: ...y to display alarms 3 To scroll through the alarm list use the key ACTIVE malfunctions AXX An alarm is active when a problem occurs on the unit the red LED is flashing speedily MALFUNCTION CODE Red LED flashes Code Description Unit shutdown Checking A00 No malfunction Unit in operation Contact your Service Center A01 Low pressure switch open Yes A02 High pressure switch open A04 Clutch open circui...

Page 14: ... is OFF It is impossible for the unit to automatically start up during maintenance 7 1 Maintenance schedule km Mile Initial service Service A Service B 5000 3000 30000 18000 60000 36000 90000 54000 120000 72000 150000 90000 180000 108000 210000 126000 7 2 Service description Initial service Check the tightness of bolts and screws and that the unit is correctly fastened onto the box Check pressure ...

Page 15: ... by a test carried out in one of the approved testing stations and ratified by an official report Note The K coefficient of equipment of classes B C E and F shall in every case be equal to or less than 0 4 W m2 C Signs identification marks and plates to be attached to mechanically refrigerated equipment Refrigeration Plate This heavy insulation must be followed by identification marks according to...

Page 16: ...RELAND 1800 553286 L LUXEMBURG 800 3581 RUS RUSSIA 810 800 200 31032 N NORWAY 800 11435 NL THE NETHERLANDS 0800 0224894 P PORTUGAL 8008 32283 PL POLAND 00800 3211238 S SWEDEN 020 790470 From other countries Direct 32 9 255 67 89 In Canada or United States call 1 800 448 1661 When calling please have the following information ready for fastest service Your name the name of your company and your loc...

Page 17: ...司的制冷机组产品进行正确的操作和保养 此机组可以长期 无故障 运行 本说明书中所概述的检查方法会帮助您将问题减小到最低程度 此外 综合保养程序会 帮助您保证机组的持续 可靠的运行 此保养程序还可以帮助控制此机组的运行费用 延长机 组的使用寿命 并提高其性能 对机组进行维修的时候 请务必使用指定的开利运输冷冻设备公司的原装备用零件 以保 障其最佳质量和可靠性 开利运输冷冻设备有限公司的全体员工正不断地提高产品性能 以满足客户的需要 因此 产品规格如发生变更 恕不另行通知 目录 前言 17 1 产品说明和产品标识 18 1 1 产品说明 18 1 2 产品标识牌 18 1 3 噪声等级标签 18 2 安全说明 18 2 1 警告标签的保养 20 3 货物装载说明 21 4 运输温度 推荐 22 5 显示板 22 5 1 操作面板说明 22 6 操作说明 23 6 1 DIN 显示器操作原理 2...

Page 18: ...些机组适用于大部分的车辆 1 2 产品标识牌 各机组通过贴在机框架上的标识牌进 行识别 标识牌上有机组完整的型号 系列 号以及其它一些信息 如果机组出现故障 请查看标识牌上的信息并把型号和系列号 记下 然后打电话寻求帮助 联系技术人员 之后请提供这些信息 好让他们提供正确帮 助 很容易在机组架上找到完整的标识牌 1a 也很容易在机组的侧面找到附加的系 列号 1b 1 3 噪声等级标签 噪 声 等 级 标 签 显 示 噪 声 等 级 单 位 Lwa 声功率级 2 安全说明 本说明书包含安全以及维修方面的操 作步骤 用户须遵守这些步骤以免事故发生 以下标签中的一些标签已贴在产品上 以提 示安全信息 使用本制冷机组之前 先仔细阅读本说明书中所 述的以及产品上标有的全 部的安全信息 使用本制 冷机组的任何人员必须提 前接受培训 然后才可以 安全地使用本机组 使用或保养本制冷机组的过程中 须留意安 ...

Page 19: ...认机组处于关机状态 确保机组不会重新起动 如上述 对机组的电源处 进行上锁并标识 Lock out tag out 如有防护结构 例如 风扇格栅或防护装置等 确认它们是否装在适当的位置 制冷机组正在运转 时 千万不要拆卸这些防护结构 操作人员的手 身体部位 衣服 头发以及工具等 必须远离转动部件 制冷剂 本制冷机组内 的制冷剂如果 喷到或直接触 到 皮 肤 或 眼 睛 会导致冻 伤 严重烧伤 或失明 制冷剂如果接触到火焰或热 会产生有毒气体 任 何火焰 被点燃物或火苗都要远离制冷机组 处 理 制 冷 剂 时 必须穿戴 个 人 防 护 装 备 防护服 防护手套以及 防护眼镜 有资格的人员才能进行制冷剂的处理作业 制冷剂的使用与处理方法 可燃性 HCFC 制冷剂与压力升高时的高浓度空气 进行混合便变成可燃物 此制冷剂包括R 134a 和 R404A 因此 在泄漏检查或其它用途上 这些制冷剂不 ...

Page 20: ...会放出少量的 易燃 易爆的氢气 酸喷射到皮肤或眼 睛会引起严重的烧 伤 任何火焰 被点燃物 或火苗都要远离蓄 电池元件 对蓄电池进行处理 及充电时 必须穿戴 个人防护装备 防 护服 防护手套以及 防护眼镜 蓄电池极性的连接 须正确 当心 任何人在任何情况 下都不允许试图维 修逻辑板或显示板 如果这些部件发生 问题 请与当地的开 利运输冷冻设备经 销商取得联系并更 换部件 技术人员决不能对处理器的任何部位进行电路方面 的检查 他只能对接线端子 即线束连接的地方 进行检查 微处理器元件在不同的电压以及超低电 流状态下正常运行 电压表 跳线 断路探查试验 器等装置的不正确使用会导致微处理器永久性损 坏 大部分电子元件容易遭受由静电释放 ESD 引起 的损坏 有时 人体本身也可以携带充分的静电 以致人体 一接触电子元件就会对其造成损坏 这种现象在卡 车 拖车微处理器的集成电路上特别明显 环境 本制...

Page 21: ...除热效果 这 种 堆 积 方 法 叫 做 货 物 空 堆 AIR STACKING 然而 肉 冷冻食品之类的 非产生热量的货物应该相互紧密地堆积在 箱子中央 所有的产品距车厢的侧壁须保持一定 的距离 使空气可以在箱壁和货物之间循环 避免由于车厢壁渗透的热量损坏货物 对被装载的货物进行测温是非常重要的 这 样可以保证货物运输中合适的温度 请注意 制冷机组的设计目的是将货物的温度维持 在货物被装载时的温度水平 而不是将高温 货物进行冷却 一些建议事项 装货前 通过大约15分钟的降温对车厢箱体的内 部进行预冷 用手动除霜模式可对车厢进行除湿 对于 CITIMAX500 700机型 化霜模式的启动需 要车厢温度达到一定值 9ºC 以下 蒸发器风扇受防护格栅的保护 机组处于 重载使用状态时 格栅会结冰 因此 推荐 用小毛刷定期对格栅进行清洗 停机后方可 进行清洗作业 装货时 停机后 进行装货 建议尽...

Page 22: ...闭 以便 维持其它隔间里面货物的温度并保持制冷 机组的正确运行 5 显示板 CITIMAX 系列提供两种不同形式的显 示板 分别为DIN 显示器和 SMART显示器 如下图所示 DIN控制器 SMART控制器 5 1 操作面板说明 阅读说明书时请保存好折页部分 免得 不小心被撕掉 使用此功能会使所有的控制操作程序 简单化 驾驶员在座位上就可以执行所有的 控制操作程序 停机 自动起动 调节设定 值 化霜 按照自己的要求对机组的操作进 行自定义设置 而且出现故障时可处理错误 信息等 驾驶员还可以通过显示面板将车厢箱 体的温度显示出来 然后通过检查蓝色或橙 色指示灯来确认温度是否维持在设定值 如 出现故障 红色故障指示灯会亮起 如果蓄 电池电压太低 自防故障安全系统将关闭机 组 当蓄电池电压回升至正常电压值时 机 组将自动延时重新启动 DIN显示器 SMART显示器 1 显示 4 位 4 位 2...

Page 23: ...进行编程使蒸 发器风扇连续运转 化霜 仅适用于Frozen机组 化霜操作为全自动过程 但也可以用手 动方式进行控制 化霜周期由集成微处理器全面控制 在化霜期间蒸发器风扇将停止运转 而冷凝器风扇则由微处理器控制 计时器或化霜温度传感器控制化霜周 期的终止时间 在化霜周期内 驾驶室控制显示器显示 dF 制热 仅适用于有制热功能的Frozen 机组 制热过程由热气旁通系统提供 在制热过程中 蒸发器风扇转动 而冷 凝器风扇则由微处理器控制 6 1 1 机组的起动步骤 1 起动汽车发动机 2 按下 键 起动制冷机组 延时 50秒后机组会运转 3 驾驶室控制板的数字显示器显示车厢的 温度 4 按下 键 检查温度设定值是否正 确 在数字显示器上温度设定值以加亮的 形式显示 5 必要时 输入新的设定值 参考 温度 设定值的修改步骤 第6 4段 如果起动困难 检查有无以下现象 与汽车相接部分所使用的保险丝是...

Page 24: ...显示步骤 报警 软件版本 运行时间 箱体温度等 1 按下 键5秒钟 启用故障代码的显 示功能 参考 故障报警显示功能 第6 8 段 2 按下 键或 键 显示报警 功能 3 按下 键 显示控制器软件版本 4 按下 键 显示操作面板软件版本 5 按下 键 显示总运行时间 6 按下 键 回到车厢温度的显示状 态 6 1 6 系统设定参数的修改步骤 1 将 键 键和 键同 时按下 显示最低设定温度值 2 按下 键或 键 改变最低 设定温度值 0 C 20 C 或 29 C 默认设 定值 29 C 3 按下 键 显示启动温差范围参数 4 按下 键或 键 调整变化 范围 Dif1 1 C Dif2 2 C Dif3 3 C 默 认设定值 Dif2 5 按下 键 显示停机状态下蒸发器 风机的运行模式 6 按下 键或 键 改变蒸发 器风扇的运行模式 OFF 或 ON 默认设 定值 OFF 7 按下 键 显...

Page 25: ...温度设定值超出范围 29 C 30 C 参数丢失 b 直接显示 备注 故障一被检测到 温度显示值就会消失 取而代之的是直接显示故障信息 而且此信息在故障 现象的持续期间一直会显示 故障消失或被排除之后 制冷机组方可开始运转 代码 说明 是否停机 检查 机型 EE 蒸发器温度探头 断路 短 路 是 蒸发器温度探头以及 接插头 280 350 400 500 700 EEE 化霜退出温度探头 断路 短路 否 化霜温度探头以及接 插头 280 350 400 bAt 蓄电池低电压报警 是 蓄电池电压 12VDC 24VDC交流发电机 接 插头 280 350 400 500 700 con 通讯错误 否 通讯线接口是否正常 通讯线是否正常 280 350 400 500 700 Err 用户在对最高或最低设定值 进行设置时出现错误 否 设定值 280 350 400 500 700 6 2 SM...

Page 26: ...键 检查温度设定值是否正 确 在数字显示器上温度设定值以加亮的 形式显示 5 必要时 输入新的设定值 参考 温度 设定值的修改步骤 第6 4段 如果起动困难 检查有无以下现象 与汽车相接部分所使用的保险丝是否熔 断 如保险丝正常 请与当地的开利服 务中心取得联系 驾驶室控制板所选择的温度变化 6 2 2 停机 短时间停机 如果是短时间停机 关闭 车内的点火开关 拔出钥匙即可 长时间停机 如果是长时间停机 则需 要按下控制器上的 键 6 2 3 温度设定值的修改步骤 重要 调节设定状态时 如果5秒钟内不按任何键 系统会自动回到车箱温度的显示状态 所 有的修改都会被存下来 如果驾驶室操作面板装在汽车控制面 板里面 操作面板的安装须尽量远离高温管 道 最高暴露温度 85 C 1 按下 键 显示温度设定值 2 按下 键或 键 改变设定值 3 按下 键 回到车厢温度的显示状 态 6 2 4 化霜参数...

Page 27: ...风机的运行模式 6 按下 键或 键 改变蒸发器风扇 的运行模式 OFF 或 ON 默认设定值 OFF 7 按下 键 显示单位选择 C和 F 8 按下 键或 键 选择所需的单 位 C或 F 默认设定值 C 9 按下 键 回到车厢温度的显示状 态 6 2 7 故障报警显示功能 a 通过 键进入报警显示 1 5秒之内按下 键5秒种 显示故障代 码 2 按下 键或 键 显示报警功能 3 用 键来滚动报警功能列表 故障显示功能的启用 ACTIVE A 如果机组出现问题 报警功能会被启用 红色LED指示灯会快速闪亮 故障代码 MALFUNCTION CODE 红色LED指示灯闪亮 代码 说明 是否停机 检查 A00 无故障 机组正常运行 与用户当地的服 务中心取得联系 A01 低压开关断开 是 A02 高压开关断开 A04 压缩机离合器开路 否 A06 冷凝器电机短路 A07 蒸发器电机短路 A09 ...

Page 28: ...在对最高或最低设定值 进行设置时出现错误 否 设定值 280 350 400 500 700 7 保养说明 综合保养程序会帮助用户保障机组持 续 可靠的运行 此保养程序还可以帮助控制运行费用 延长机组的使用寿命 并提高其性能 备注 一切保养作业必须由完成开利产品安 全以及质量方面所有标准培训的技术人员 进行 需要对机组进行应急作业时 检查以下 情况 停机 驾驶室控制装置 在保养期间 机组不能自动起动 7 1 保养计划 公里 英里 第一次 保养 保养A 保养B 5000 3000 30000 18000 60000 36000 90000 54000 120000 72000 150000 90000 180000 108000 210000 126000 7 2 维修说明 第一次保养 检查螺栓与螺丝的松紧度 并检 查机组是否正确地固定在车箱上 检查有无泄漏现象 检查压缩机每分钟转数 RPM...

Page 29: ...冷系统的 封闭单元 外面平均温度为 30 C的环境下 此机组可以将空车厢内部的温度降下来并 通过以下方式维持其低温状态 A级 机械制冷设备配有制冷系统 因此可 以在 12 C 0 C的温度范围内 12 C和 0 C包括在内 进行选择 B级 机械制冷设备配有制冷系统 因此可 以在 12 C 10 C的温度范围内 12 C 和 10 C包括在内 进行选择 C级 机械制冷设备配有制冷系统 因此可 以在 12 C 20 C的温度范围内 12 C 和 20 C包括在内 进行选择 D级 对于配有冷冻装置的机械制冷设备 ti小于或等于0ºC E级 对于配有冷冻装置的机械制冷设备 ti小于或等于 10ºC F级 对于配有冷冻装置的机械制冷设备 ti小于或等于 20ºC 机组能力由认证机构进行测试后决定 而且通过发放正式报告书给予批准 备注 B级 C级 E级和F级设备的K系数在 任何情况都应小于或等于0 4...

Page 30: ...费电话号码 A 奥地利 0800 291039 B 比利时 0800 99310 CH 瑞士 0800 838839 D 德国 0800 1808180 DK 丹麦 808 81832 E 西班牙 99 993213 F 法国 0800 913148 FIN 芬兰 0800 113221 GB 英国 0800 9179067 GR 希腊 00800 3222523 H 匈牙利 06800 13526 I 意大利 800 791033 IRL 爱尔兰 1800 553286 L 卢森堡 800 3581 RUS 俄罗斯 810 800 200 31032 N 挪威 800 11435 NL 荷兰 0800 0224894 P 葡萄牙 8008 32283 PL 波兰 00800 3211238 S 瑞典 020 790470 从其它国家 直拨 32 9 255 67 89 在加拿大或美国 拨...

Reviews: