Figure 1.
10
- Attaching Switched 12
VDC Power Wire
h. Locate the F27A/ST3 wire in the control box. Cut the black insulation off the end of the wire and
strip insulation back 0.31”. Insert the stripped end of the wire to the eSolutions harness wire
labeled SP80B and crimp the butt splice and apply heat shrink. The remaining wire labeled SP80C
is present for Fuel Heat if that option is used on the Supra.
Figure 1.1
1
- Attaching Constant 12
VDC Power Wire
NOTE
See Tools: Stripping Wire, Crimping, Heat Shrink
SP80C
22-03090-00
SP80B
F27A/ST3
1J
Socket
(950MT uses 3J )
Insert wire 1J-12
(950MT
uses 3J-12)
into butt splice
on new harness wire
labeled SP81B. Use
proper crimping tool and
supplied heat shrink.
8
62-12110
New terminal for 1J plug,
pin 12 position
(950MT uses 3J-12)
22-03090-00
1J plug
(
950MT uses 3J)
Insert wire 1J-12 (950MT
uses
3J-12)
into butt splice
on new harness wire labeled
SP81B. Use proper crimping
tool and supplied heat shrink.