2-9
62-10848
2.6.3
Electrical Data
Fan Motors
Standby Compressor Speed
1740 rpm - 60 hz
Standby Motor Ratings
* MRA = Maximum Rotor Amps LRA = Locked Rotor Amps
Resistance = 9.2
Ω
Road Compressor Clutch
Amp Draw = 3.75A; Resistance = 3.2
Ω
Hot Gas Solenoid Valve (HGS1) Coil
Amp Draw = 1.33 Amp; Resistance = 9.2
Ω
Condenser Pressure Control Valve (HGS2) Coil
Amp Draw = 1.65 Amp; Resistance = 7.3
Ω
Quench Valve (BPV) Coil
Amp Draw = 1.16 Amp; Resistance = 10.3
Ω
Standby Motor Contactor Coil
Amp Draw = 0.19 Amp; Resistance = 60
Ω
2.6.4
Torque Values
Table 2–4 Fan Motors Data
Evaporator Fan Motor (EFM)
Condenser Fan Motor (CFM)
Bearing Lubrication
Factory Lubricated
Bearing Lubrication
Factory Lubricated
Horsepower
0.1 kw
Operating Amps
10.8 amps
Operating Amps
10 amps
Speed
2800/3000 rpm
Speed
3300 rpm
Table 2–5 Standby Motor Ratings
Voltage
Type of Connection
Phase
kW
HP
Speed
Contractor Data
MRA*
LRA*
115/1/60
Δ
1
1.5
2
1745 rpm
18.3
132.5
208/1/60
Δ
1
1690 rpm
9.2
70
230/1/60
Δ
1
1715 rpm
8.5
60
230/3/60
Δ
3
1700 rpm
5.9
40
Table 2–6 Torque Values
Assembly
ft-lb
kg-m
Standby compressor platform
40
5.5
Standby motor platform
40
5.5
Standby motor pulley
32
4.5
Evaporator fan motor
13
1.8
Evaporator fan
7
1.0
Condenser - frame
7
1.0
Mounting Bolts
44 to 60
6 to 8