1-3
62-12023
CAUTION
!
Under no circumstances should anyone attempt to repair the microprocessor module or either
Cab Command module! Should a problem develop with these components, contact your near-
est Carrier Transicold dealer for replacement.
CAUTION
!
If starting unit for the first time after installation the compressor pressure regulating valve will
need to be reset (refer to
CAUTION
!
If starting unit for the first time after installation or starting after adding/removing an optional
feature or if Owners operating parameters have changed the Configuration will need to be
reset.
CAUTION
!
To prevent trapping liquid refrigerant in the manifold gauge set be sure set is brought to suc-
tion pressure before disconnecting.
CAUTION
!
When working with refrigerant use safety glasses and gloves to avoid burns. Hoses and cop-
per tubing can be hot when unit is running.
CAUTION
!
Refrigerant R-404A is a blend. Charging as a vapor will change the properties of the refrigerant.
Only liquid charging through the king valve is acceptable.
CAUTION
!
Do not damage or over tighten the enclosing tube assembly. Also all parts must be placed in
the enclosing tube in proper sequence to avoid premature coil burn-out.