62-12023
2-8
c. Standby Motor Ratings
c. Road Compressor Clutch (CLHR) Coil
Amp Draw = 3.75A; Resistance = 3.2
Ω
d. Hot Gas Solenoid Valve (HGS1) Coil
Amp Draw = 1330 mAmp; Resistance = 10.1
Ω
e. Condenser Closing Valve (HGS2) Coil
Amp Draw = 1650 mAmp; Resistance = 7.2
Ω
f. Quench Valve (BPV) Coil
Amp Draw = 1160 mAmp; Resistance = 10.3
Ω
2.7
Torques Values Safety Devices
Voltage
kW
HP
Contactor Data - MRA*
115/1/60Hz
1.5
2
23.2A
230/1/60Hz
11.7A
230/3/60Hz
8.9A
* MRA = Maximum Rotor Amps
Assembly
Ft-Lbs
N-m
Standby compressor platform
40
7.5
Standby motor platform
40
7.5
Standby motor pulley
40
7.5
Compressor pulley
22
29.8
Evaporator fan motor
13
17.6
Condenser - frame
18
24.4
Mounting bolts
44 to 60
8 to 11