3-5
62-12023
c. Keypad
The keypad consists of six keys that enable the operator to activate various functions, display operating data and
modify operating parameters.
Unit Data and Function Modification Keys
NOTE
If no keys are pressed within five seconds of pressing the ON key, the system reverts to box temperature.
d. Additional Key Functions
To access additional key functions, press and hold the SET key for five seconds. The microprocessor will provide a
set of additional functions as the SET key is pressed additional times after the five-second hold. The sequence for
the additional functions is as follows:
NOTE
If no keys are pressed within five seconds of pressing the ON key, the system reverts to box temperature.
Manual defrost control key
Unit start-up key
Unit shut-down key in standby or road mode
In road operation, the unit can also be shut down with the ignition key.
The SET key, together with the + and - keys, enables display and modification of unit
operating data. The display changes parameters each time the SET key is pressed.
Decrease key for selected data
Increase key for selected data
1. Press SET for five seconds. This enables access to the alarm codes.
2. Press to display the alarm list.
3. Press SET again to display software versions.
4. Press + to display the cab command software version.
5. Press SET again to display road hour meter (Road LED ON).
6. Press SET again to display standby hour meter (Standby LED ON).
7. Press DEFROST to display the present interval between defrosts (min) as calculated by
the microprocessor.
8. Press DEFROST to display the elapsed time (min) since the last defrost.
9. Press SET to return to box temperature.
Summary of Contents for Integra 35X
Page 2: ......
Page 8: ......
Page 12: ......
Page 68: ......
Page 69: ...wiring schematics ...
Page 70: ......
Page 71: ...wiring schematics ...
Page 72: ......
Page 73: ...wiring schematics ...
Page 74: ......
Page 75: ...wiring schematics ...
Page 76: ......
Page 79: ......