6-1
62-12023
SECTION 6
Troubleshooting
WARNING
!
Beware of unannounced starting of the unit. The unit may cycle the fans and one of the operat-
ing compressors unexpectedly as control requirements dictate. To ensure unit is without
power, remove power plug and remove battery negative cable.
CAUTION
!
Under no circumstances should anyone attempt to service the microprocessor (see
) or either Cab Command module. Should a problem develop with the microprocessor,
contact your nearest Carrier Transicold dealer for replacement.
6.1
Introduction
Table 6–1 Alarm Indications
Alarm
Description
Corrective Action
Reference
A00
No Alarms
All components functioning normally
-
A01
(A02 -
Alternating
Alarm)
Road Only
Low Pressure Switch
(LP) Open
Unit undercharged
Liquid line filter drier restricted
TXV strainer plugged with foreign material/ice
TXV not functioning properly
Verify operation of evaporator fans
--
Failed switch
High Pressure Switch
(HP1) Open
Unit overcharged
Verify operation of condenser fan
--
Noncondensibles in system
Failed switch
A01
Low Pressure Switch
(LP) Open (Road)
Unit undercharged
Liquid line filter drier restricted
TXV strainer plugged with foreign material/ice
TXV not functioning properly
Verify operation of evaporator fans
--
Failed switch
A02
High Pressure Switch
(HP1) Open
Unit undercharged
Verify operation of condenser fan
--
Noncondensibles in system
Discharge check valve failed closed (standby or road)
Replace
Failed switch
A03
Standby Compressor
Thermal Overload open
Check liquid injection valve
Electric line voltage low
Summary of Contents for Integra 35X
Page 2: ......
Page 8: ......
Page 12: ......
Page 68: ......
Page 69: ...wiring schematics ...
Page 70: ......
Page 71: ...wiring schematics ...
Page 72: ......
Page 73: ...wiring schematics ...
Page 74: ......
Page 75: ...wiring schematics ...
Page 76: ......
Page 79: ......