6-4
Table 6–2 Mechanical Indications
Indication/Trouble
Possible Causes
Reference
6.2
Refrigeration
6.2.1
Unit Will Not Cool
Compressor not functioning prop-
erly
Compressor drive (clutch) defective
Compressor defective
Replace
Refrigeration system
Defrost cycle has not terminated
Abnormal pressure
Hot gas solenoid not functioning properly (HGS1)
6.2.2
Unit Runs But Has Insufficient Cooling
Compressor
Compressor defective
Replace
Refrigeration system
Abnormal pressure
Expansion valve not functioning properly
No or restricted evaporator airflow
6.2.3
Unit Operates Long or Continuously in Cooling
Box
Hot Load
Defective box insulation or air leak
Insufficient pull
down time
Correct
Refrigeration system
Abnormal pressure
Temperature controller not functioning properly
Compressor
Defective
Replace
6.2.4
Unit Will Not Heat or Heating Insufficient
Refrigeration
Abnormal pressure
Temperature controller not functioning properly
Hot gas solenoid not functioning properly (HGS1)
Compressor
Compressor drive (clutch) defective
Compressor defective
Check
Replace
6.2.5
Defrost
Automatic defrost will not initiate
Defrost thermostat (DTT) open or defective
Hot gas valve not functioning properly
Defrost disabled through cab command
Replace
Manual defrost will not initiate
Microprocessor defective
Defrost thermostat (DTT) open or defective
Replace
Replace
Defrost cycle initiates but does not
defrost
Hot gas solenoid not functioning properly (HGS1)
Condenser Pressure Control valve not functioning properly
(HGS2)
Frequent defrost
Wet load
Defrost settings set to low
--
Does not terminate or cycles on
defrost
Defrost thermostats (DTT) shorted closed
Replace
Summary of Contents for Integra 35X
Page 2: ......
Page 8: ......
Page 12: ......
Page 68: ......
Page 69: ...wiring schematics ...
Page 70: ......
Page 71: ...wiring schematics ...
Page 72: ......
Page 73: ...wiring schematics ...
Page 74: ......
Page 75: ...wiring schematics ...
Page 76: ......
Page 79: ......