6-5
62-12023
6.2.6
Abnormal Pressure
Cooling
High discharge pressure
Condenser coil dirty
Noncondensibles or refrigerant overcharge
Condenser fan/motor defective
Low discharge pressure
Compressor defective
Hot gas solenoid not functioning properly
Low refrigerant charge
Replace
High suction pressure
Compressor defective
Hot gas solenoid not functioning properly
Compressor pressure regulator mis-adjusted (CPR)
Replace
Low suction pressure
Filter drier partially plugged
Low refrigerant charge
Expansion valve not functioning properly
No evaporator air flow or restricted air flow
Excessive frost on coil
Check
Suction and discharge pressures
tend to equalize when unit is oper-
ating
Compressor defective
Hot gas solenoid not functioning properly
Replace
Heating
High discharge pressure
Overcharged system
Condenser fan or HP2 pressure switch defective
Noncondensibles in system
Condenser motor/fan defective
HGS2 closed
Low discharge pressure
Compressor defective
Hot gas valve not functioning properly
Replace
Low suction pressure
Low refrigerant charge
Compressor pressure regulating valve mis-adjusted (CPR)
Condenser Pressure Regulating valve fault (HGS2)
6.2.7
Abnormal Noise
Compressor
Loose mounting bolts
Worn bearings
Worn or broken valves
Liquid slugging
Insufficient oil
Tighten
Replace
Replace
Check
Condenser or evaporator fan
Loose shroud
Bearings defective
Fan loose on shaft
Bent shaft
Check
Check
Check
6.2.8
Cab Command /Cab Command Two
Cab Command Not Functioning
Properly
Microprocessor fuse open
Microprocessor not functioning properly
Microprocessor/Cab command cable
Replace
Replace
Check
Table 6–2 Mechanical Indications (Continued)
Summary of Contents for Integra 35X
Page 2: ......
Page 8: ......
Page 12: ......
Page 68: ......
Page 69: ...wiring schematics ...
Page 70: ......
Page 71: ...wiring schematics ...
Page 72: ......
Page 73: ...wiring schematics ...
Page 74: ......
Page 75: ...wiring schematics ...
Page 76: ......
Page 79: ......