62-12023
5-2
5.2
Installing R-404A Manifold Gauge Set
A manifold gauge/hose set is required for service of models covered within this manual. The manifold gauge/hose
set is available from Carrier Transicold. (Carrier Transicold P/N 07-00314-00, which includes items 1 through 4,
). To perform service using the manifold gauge/hose set, do the following:
Table 5–4 Preventive Maintenance Schedule - Standby
Hours
Service A
Service B
Service C
Service D
100
•
1000
•
•
2000
•
•
•
3000
•
•
4000
•
•
•
•
5000
•
•
6000
•
•
•
7000
•
•
Table 5–5 Service Category Descriptions
Service A
1. Check the tension of the alternator belt(s).
2. Check that the vehicle engine runs correctly at low speed, and that the
compressor mounting kit is correctly tightened and the belt tension is cor-
rect.
3. Check the tightness of bolts and screws and that the unit is correctly fas-
tened onto the box.
4. Check tension of alternator/compressor belt.
Service B
1. Clean condenser and the evaporator coils. (
and
)
2. Replace the road compressor belt.
3. Check, and if required, replace the filter drier. (
4. Check the operation of cab command.
5. Check the defrost:
• Cut-in
• Fan shut-down
• Cut-out
• Defrost water drain(s)
Service C
1. Check the operation of the evaporator and condenser fans. Change the
condenser motor brushes. The evaporator of this unit is equipped with
brushless fan motors therefore, brush maintenance is not required.
2. Change the compressor oil. Use polyol ester oil (POE) approved by CAR-
RIER. Refer to
Service D
1. Change the removable fuses and capacitors (if any) in the control box.
Summary of Contents for Integra 35X
Page 2: ......
Page 8: ......
Page 12: ......
Page 68: ......
Page 69: ...wiring schematics ...
Page 70: ......
Page 71: ...wiring schematics ...
Page 72: ......
Page 73: ...wiring schematics ...
Page 74: ......
Page 75: ...wiring schematics ...
Page 76: ......
Page 79: ......