T-372
4–18
Generic Mode
The Generic Mode allows user selection of the network data points to be recorded. The user may select up to a
total of eight data points for recording. Changing the configuration to generic and selecting which data points to
record may be done using the Carrier Transicold Data Retrieval Program. A list of the data points available for
recording follows.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
5. Phase A current
6. Phase B current
7. Phase C current
8. Main voltage
9. Evaporator expansion valve percentage
10. Discrete outputs (Bit mapped - require special handling if used)
11. Discrete inputs (Bit mapped - require special handling if used)
12. Ambient temperature sensor (AMBS)
13. Evaporator temperature sensor (ETS)
14. Compressor discharge temperature sensor (CPDS)
15. Return temperature sensor (RTS)
16. Supply temperature sensor (STS)
17. Defrost temperature sensor (DTS)
18. Discharge pressure transducer (DPT)
19. Suction pressure transducer (SPT)
20. Evaporator pressure transducer (EPT)
21. Vent position sensor (VPS)
4.6.5
Logging Interval (dCF03)
The user may select four different time intervals between data recordings. Data is logged at exact intervals in
accordance with the real time clock. The clock is factory set at Greenwich Mean Time (GMT).
6 sensors (dCF02=54)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 cargo probe (thermistor input)
7 sensors (dCF02=64)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)
9 sensors (dCF02=9)
Not Applicable
Table 4–5 DataCORDER Standard Configurations
Standard Config
Description