4–25
T-372
4.7.2.e Communicating with the Controller using DataLINE Connect (Android Device)
This procedure explains how to open the DataLINE Connect application and connect it directly to a unit’s controller.
1. Open the DataLINE Connect application.
2. Open the WiFi Settings menu (or Settings menu).
3. Verify that the “Wi-Fi ON” indicator is enabled.
4. Under “Wi-Fi Login Credentials”, specify the name of the wireless connection next to “Container ID” by
selecting from the list of available WiFi connections, or by typing in the Container ID of the unit you want to
connect to.
5. Next to “Passcode” (or “Token”), enter the passcode obtained from the Net menu on the display if it is not
6. Select Login.
7. The message will appear “Connected to the WIFI successfully”. The controller wireless network name
appears on the top right corner of the interface.
8. After clicking OK to the message, the features of DataLINE Connect are now available. Refer to DataLINE
Connect user manual for more detailed procedures for using DataLINE Connect.
4.8 Controller Configuration Variables
Table 4–7 Controller Configuration Variables
Config
Title
Default
Option
CnF02
Evaporator Fan Speed
dS (Dual)
SS (Single)
CnF03
Control Temperature Sensors
FOUr
duAL
CnF04
Enable Dehumidification
On
OFF
CnF08
Evaporator Motor Type
1Ph
3Ph
CnF09
Refrigerant Type
r134a
r744
CnF11
Defrost “Off” Selection
noOFF
OFF
CnF15
Enable Discharge Temperature Sensor
Out
In
CnF16
Enable DataCORDER
On (Yes)
(Not Allowed)
CnF17
Enable Discharge Pressure Sensor
Out (No)
In (Yes)
CnF18
Heater Type
Old (Low Watt)
nEW (High Watt)
CnF20
Enable Suction Pressure Transducer
Out (No)
In (Yes)
CnF22
Economy Mode
OFF
Std, Full
CnF23
Enable Defrost Interval Save
noSAv
SAv
CnF24
Enable Long Pre-Trip Test Series
Auto
Auto2, Auto 3
CnF25
Enable Pre-Trip Data Recording
rSLtS
dAtA
CnF26
Heat Lockout Temperature
Set to -10C
Set to -5C
CnF27
Enable Suction Temperature Sensor
Out
In
CnF28
Enable Bulb Mode
NOr
bULb
CnF31
Probe Check
SPEC
Std
CnF32
Enable Single Evaporator Operation
2EF0
(Not Allowed)
CnF33
Enable Snap Freeze
OFF
SnAP
CnF34
Temperature Unit Display
nOth
F
CnF37
Electronic Chart Probe
rEtUR
SUPPL, bOth
CnF41
Enable Low DTT Setting
Out
In
CnF44
Autoslide Enable
Out
LO, UP