Cd48 Dehumidification / Bulb
Cargo Mode Parameter
Selection
Initially Cd48 will display current dehumidification-mode; bUlb - bulb cargo mode,
dEhUM - normal dehumidification, or OFF - off. This display is steady.
Press the ENTER key to take the interface down into a hierarchy of parameter
selection menus (mode, setpoint, evaporator speed, DTT setting). Press the
ENTER key in any parameter selection menu to commit selection of the currently
displayed parameter and cause the interface to descend into the next parameter
selection menu. All parameter selection menus alternate between a blank display
and the current selection in the right hand display.
Press the CODE SELECT key in a selection menu to cancel the current selection
activity and ascend back up to the next higher selection menu (or to Cd48 display
mode if that is the next higher).
If the operator does not press any key for five seconds, the interface reverts to
normal system display and the current selection menu is cancelled, but any
previously committed changes are retained.
Available parameters and parameter ranges are a function of configuration
options and previously selected parameters as indicated above.
Whenever any pre-trip test is initiated, dehumidification-mode goes to OFF.
Whenever dehumidification-mode goes to OFF:
• Dehumidification control setpoint goes to0%RHinternally but will then ini
-
tialize to 95% RH when dehumidification-mode leaves OFF.
• Evaporator speed select goes to Alt for units without PWM Compressor
Control (Cnf57 = Out), Evaporator speed select goes to Hi for units with
PWM Compressor Control (Cnf57 = In).
• DTT setting goes to 25.6_C or 18.0_C, depending on Cnf41.
Whenever dehumidification-mode is set to bUlb, DTT setting goes to 18.0°C if it
had been set higher.
Whenever dehumidification-mode is set to dEhUM, DTT setting goes to 25.6°C
or 18.0°C, depending on Cnf41.
For units without PWM Compressor Control (Cnf57 = Out):
• Whenever dehumidification control setpoint is set below 65% RH evapo
-
rator speed select goes to LO if it had been set to Hi.
• Whenever dehumidification control setpoint is set above 64% RH evapo
-
rator speed select goes to Alt if it had been set to LO.
For units with PWM Compressor Control (Cnf57 = In):
• Whenever dehumidification control setpoint is set below 60% RH, the
evaporator fan speed is set to LO, the user has the ability to set the evap
-
orator fan speed to Hi via the keypad.
• Whenever dehumidification control setpoint is set equal to or above 60%
RH, the evaporator fan speed is set to Hi, the user has the ability to set
the evaporator fan speed to LO via the keypad.
Display Only Function
- Cd49 is a display only function.
Cd49 Days Since Last
Successful Pre-Trip
Displays the number of days since last successful pre-trip sequence.
Press the ENTER key to view the number of days since the last successful pre-
trip for Auto1, Auto2, and Auto2 in sequence.
Press the CODE SELECT key to step back through the list and ultimately to exit
the Cd49 display.
Configurable Functions
- Cd50 through Cd53 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.Cd50
Table 4–8 Controller Function Codes (Continued)
Code Title
Description