T-372
7–8
7.9 Compressor
WARNING
!
Make sure power to the unit is OFF and power plug disconnected before replacing the compressor.
WARNING
!
Before disassembly of the compressor, be sure to relieve the internal pressure very carefully
by slightly loosening the couplings to break the seal.
CAUTION
!
The scroll compressor achieves low suction pressure very quickly. Do not use the compressor
to evacuate the system below 0 psig. Never operate the compressor with the suction or
discharge service valves closed (frontseated). Internal damage will result from operating the
compressor in a deep vacuum.
CAUTION
!
The PrimeLINE unit has a hermetically sealed compressor that should not be opened and/or
repaired. Doing so can cause a loss in performance and premature system failure due to the
precision machinery and assembly required within the compressor. To repair the unit, remove
the faulty compressor and replace with an approved Carrier compressor. If the return of the
compressor is not required, follow local waste collection & recycling regulations in discarding
the compressor.
NOTICE
Replacement compressors are supplied without oil.
7.9.1
Removal and Replacement of Compressor
1. Turn the unit ON and run it in full cool mode for 10 minutes.
NOTE
If the compressor is not operational, frontseat the suction and discharge service valves and go to step 5 below.
2. Frontseat the manual liquid line valve and allow the unit to pull-down to 0.1 kg/cm2 (1 psig).
3. Place the Start-Stop switch (ST) to “0”, turn the unit circuit breaker (CB-1) OFF, and disconnect power to the unit.
4. Frontseat the discharge and suction service valves.
5. Remove all remaining refrigerant from the compressor using a refrigerant recovery system.
6. Remove the compressor terminal cover, disconnect the ground wire and pull the cable plug from the
compressor terminals. Install the terminal cover back after removing the power cable.
NOTE
Inspect the power cable (plug) terminals to ensure they are not deformed or have any signs of heat or
arcing. If any damage is noted, replace the power cable.
7. Remove the Rotalock fittings from the suction and discharge service connections, and uncouple the
unloader and economizer lines from the compressor.
8. Cut the dome ambient temperature sensor (CPDS) wires. The replacement compressor comes with a
CPDS already assembled.
9. Remove and save the compressor base mounting bolts. Discard the four top resilient mounts and washers.
10. Remove (slide out) the old compressor from the unit.