EVAC / CHARGE MODE
The unit is in Service Mode, and the refrigeration system is ready to
be evacuated then charged with refrigerant. Refer to
.
EXITING PRETRIP MODE
Pretrip has been aborted either by user or by a pretrip alarm.
EXITING SERVICE MODE
Service Mode has been turned off and unit is returning to normal op-
eration.
INACTIVE ALARMS IN MEMORY
There are inactive alarms in the microprocessor alarm list which
have not yet been cleared.
INTELLI-SLEEP MODE
The IntelliSleep IntelliSet is active. This message alternates with
“CHANGE INTELLISET TO EXIT” at 5 second interval whether unit
is running or not.
KEYPAD (display mounted keys)
LOCKED-BATTERY TOO LOW
Once the battery voltage goes below 7.0 Volts for 10 seconds, all of
the keys on the display will be locked.
LOSS OF COMMUNICATIONS
There is a loss of communications between the display module or
other modules(s). If a specific module is involved, the name of the
module will also be indicated.
MAX SETPOINT HAS BEEN REACHED
Maximum setpoint allowed by configuration settings has been
reached.
MICRO WILL RESET & RESTART NOW
The microprocessor program software has just been changed, or a
new configuration has been programmed into the microprocessor.
The microprocessor will turn itself off then on again (similar to a
computer reboot) in order for the changes to be effective.
MIN SETPOINT HAS BEEN REACHED
Minimum setpoint allowed by configuration settings has been
reached.
MODIFIED
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and one or more
of its settings have been modified.
NO ACTIVE ALARMS
There are no active alarms in the microprocessor Alarm List.
NO INACTIVE ALARMS
There are no inactive alarms in the Alarm List.
PC MODE
The START/RUN-OFF switch is in the OFF position, the unit is not
running in order to enter PC Mode.
PM DUE
Preventative Maintenance is now due on the unit. Information on
what meter(s) has timed out and the reset feature is provided under
Technician Hour Meters. Refer to
PRETRIP FAIL & COMPLETED
The Pretrip test is completed, and some of the Pretrip tests did not
pass. Check the Alarm List for Pretrip alarms.
PRETRIP FAIL IN TEST XX
Some of the Pretrip tests did not pass and the Pretrip was not com-
pleted. Check the Alarm List for Pretrip alarms.
PRETRIP PASS
All of the Pretrip tests were ok.
PRETRIP STOPPED BY USER
Pretrip has been stopped by user.
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides nor-
mal unit Start-Stop or Continuous Run operation. Refer to
.
RECORDING DATA - PLEASE WAIT MI-
CRO WILL RESTART WHEN COMPLETE
This message will be displayed when the unit is starting and the
main microprocessor is completing communicating with another
module.
Table 6–1 MessageCenter MESSAGES
Message
Description
Summary of Contents for VECTOR 8100
Page 2: ......
Page 4: ......
Page 12: ...62 11785 viii ...
Page 16: ...62 11640 12 ...
Page 18: ...62 11785 ...
Page 24: ...62 11785 1 6 1 3 SAFETY DECALS ...
Page 25: ...1 7 62 11785 ...
Page 26: ...62 11785 1 8 ...
Page 27: ...1 9 62 11785 ...
Page 28: ...62 11785 1 10 ...
Page 30: ...62 11785 ...
Page 50: ...62 11785 ...
Page 82: ...62 11785 ...
Page 96: ...62 11785 4 14 ...
Page 98: ...62 11785 ...
Page 129: ...5 31 62 11785 ...
Page 130: ...62 11785 5 32 ...
Page 134: ...62 11785 6 4 ...
Page 138: ...62 11785 ...
Page 230: ...62 11785 ...
Page 271: ...8 41 62 11785 ...
Page 272: ...62 11785 8 42 ...
Page 274: ...62 11785 ...
Page 286: ......
Page 287: ......
Page 288: ...62 11785 10 8 ...
Page 292: ......
Page 293: ......