62-11785
7–78
P11000
CHECK CONDENSER FAN MOTOR 2
• ACTIVATION: Normal draw for the condenser fan motors is 0.8 to 3.5 Amps (460 VAC). The circuit tests
outside this range.
• UNIT CONTROL: Pretrip will fail and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto Reset if Pretrip is started again, or alarm may be manually reset via keypad or
by turning the unit off, then back on again.
CORRECTIVE ACTIONS:
Check Motor
- refer to procedure for Alarm
P00190 CHECK CONDENSER FAN MOTOR
.
P13000
CHECK CONDENSER FAN 2 CIRCUIT
• ACTIVATION: Normal draw for the CDCON2 contactor coil is 0.05 to 2.0 Amps (12 VDC). The circuit tests
outside this range.
• UNIT CONTROL: Pretrip will fail and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto Reset if Pretrip is started again, or alarm may be manually reset via keypad or
by turning the unit off, then back on again.
CORRECTIVE ACTIONS:
Refer to procedure for Alarm
P00206 CHECK CONDENSER FAN CIRCUIT
.
20100
NO COMM FROM MICRO TO DISPLAY
NOTE
This alarm will be available in the inactive alarm list and download only. It is an indication that an
intermittent failure is occurring, causing a break in the circuit sufficient to activate the alarm.
• ACTIVATION: If alarm
21100 NO COMM FROM ANY BOARD TO MAIN MICRO
is not active and main
microprocessor cannot communicate with the display module over the CAN bus.
• UNIT CONTROL: Required Shutdown. If alarm remains active for 2 minutes issue a shutdown command to
all modules except the display.
• RESET CONDITION: Auto reset when CAN communication is restored, or alarm may be manually reset by
turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
Check CAN bus
a. Inspect connector pins & terminals on 1MM, 1SVM and DM. No damaged or corrosion in connections.
b. Check display. LOSS OF COMMUNICATIONS message is displayed.
c. Check for CAN circuit continuity: CAN Hi; Refer to
. CAN Lo; Refer to
. If
good continuity is not present, check connectors and wiring between terminals for damage,
moisture or corrosion.
Summary of Contents for VECTOR 8100
Page 2: ......
Page 4: ......
Page 12: ...62 11785 viii ...
Page 16: ...62 11640 12 ...
Page 18: ...62 11785 ...
Page 24: ...62 11785 1 6 1 3 SAFETY DECALS ...
Page 25: ...1 7 62 11785 ...
Page 26: ...62 11785 1 8 ...
Page 27: ...1 9 62 11785 ...
Page 28: ...62 11785 1 10 ...
Page 30: ...62 11785 ...
Page 50: ...62 11785 ...
Page 82: ...62 11785 ...
Page 96: ...62 11785 4 14 ...
Page 98: ...62 11785 ...
Page 129: ...5 31 62 11785 ...
Page 130: ...62 11785 5 32 ...
Page 134: ...62 11785 6 4 ...
Page 138: ...62 11785 ...
Page 230: ...62 11785 ...
Page 271: ...8 41 62 11785 ...
Page 272: ...62 11785 8 42 ...
Page 274: ...62 11785 ...
Page 286: ......
Page 287: ......
Page 288: ...62 11785 10 8 ...
Page 292: ......
Page 293: ......