62-11785
7–82
22102
SENSOR INPUT VOLTAGE HIGH INP1
NOTE
This alarm is an indication that there is a short in the DC current transformer wiring from another
(nominal 12 VDC) circuit into the transducer or CT sensor circuit.
• ACTIVATION: Voltage from main microprocessor to the sensors is greater than 5.5 VDC.
• UNIT CONTROL: Alarm only.
• RESET CONDITION: Auto reset when sensor voltage is correct, alarm reset or alarm may be manually
reset by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Wiring
If a transducer reading is not within a reasonable range of gauge reading, check wires to sensors for
short.
• For CSP, check wiring from 2MM-20, 2MM-30 and 2MM-9.
• For EVOP, check wiring from 2MM-25, SP-20 and 2MM-17.
• For CDP, check wiring from 2MM-21, SP-20 and 2MM-10.
• For ECOP, check wiring from 2MM-28, SP-20 and 2MM-14.
2.
Check CT Wiring
- Check wires to sensor for short from another circuit. Check wiring from 2MM-29, 2MM-
12 and 2MM-23 to PCM.
3.
Replace Main Microprocessor
- Download data and replace main microprocessor. For complete Main
Microprocessor Module replacement instructions refer to
22103
INPUT LOST CONFIGURATION
• ACTIVATION: Input Board reports an invalid configuration.
• UNIT CONTROL: Required Shutdown.
• RESET CONDITION: Auto reset when communication is restored, or alarm may be manually reset by
turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 in
Section.) Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Wiring
- Check logic power connections. Check wiring at 1MM-6 & 1MM-1.
2.
Replace Main Microprocessor
- Download data and replace main microprocessor. For complete Main
Microprocessor Module replacement instructions refer to
Summary of Contents for VECTOR 8100
Page 2: ......
Page 4: ......
Page 12: ...62 11785 viii ...
Page 16: ...62 11640 12 ...
Page 18: ...62 11785 ...
Page 24: ...62 11785 1 6 1 3 SAFETY DECALS ...
Page 25: ...1 7 62 11785 ...
Page 26: ...62 11785 1 8 ...
Page 27: ...1 9 62 11785 ...
Page 28: ...62 11785 1 10 ...
Page 30: ...62 11785 ...
Page 50: ...62 11785 ...
Page 82: ...62 11785 ...
Page 96: ...62 11785 4 14 ...
Page 98: ...62 11785 ...
Page 129: ...5 31 62 11785 ...
Page 130: ...62 11785 5 32 ...
Page 134: ...62 11785 6 4 ...
Page 138: ...62 11785 ...
Page 230: ...62 11785 ...
Page 271: ...8 41 62 11785 ...
Page 272: ...62 11785 8 42 ...
Page 274: ...62 11785 ...
Page 286: ......
Page 287: ......
Page 288: ...62 11785 10 8 ...
Page 292: ......
Page 293: ......