62-11785
8–34
8. To remove motor remove four bolts that hold motor to the stator.
9. Complete the assembly in reverse order of removal. Coat motor shaft with never-seize before assembly.
10. Reinstall the negative battery cable, start unit and run Pretrip to check operation.
Torque:
Figure 8.23 Evaporator Blower Assembly
1. Access panel
2. Grille
3. Nozzle
4. Supply Air Sensor
5. Blower Assembly
6. Motor
7. Stator
8. Mounting Brackets
9. Support Bracket
- - - - -
Fan Nut
37 to 43 ft/lbs
(50 to 58 Nm)
Motor Mounting Bolts
5.5 to 7.5 ft/lbs
(7.5 to 10 Nm)
Mounting Bracket
Bolts
5 to 7 ft/lbs
(6.8 to 9.5 Nm)