13
62-11646
S
WITCHING
O
PERATING
S
TATE
- C
ONTINUED
For safe, reliable operation in Electric Operation, it is important to
consider the following guidelines:
•
NEVER
connect the unit to a high voltage power source unless the
START/RUN - OFF switch is in the OFF position.
• The power supply cable and circuit breaker must comply with local
electrical code and unit specifications.
• The power supply cable must be equipped with a ground connection.
• Repairs or maintenance to the supply voltage circuit should only be
performed by licensed/authorized personnel.
ENGINE TO ELECTRIC
1. If the standby electric cable is not already in place, ensure the unit is
powered OFF and the external power circuit breaker is OFF, and then
connect the standby electric cable to the unit receptacle.
2. Turn the external power circuit breaker ON.
3. Turn the START/RUN-OFF switch to the START/RUN position.
4. Press and release the MENU key until the STANDBY soft key is displayed.
5. Press the STANDBY soft key, the STANDBY and DIESEL soft keys will
display.
6. Press the STANDBY soft key to place the unit in Electric operation. The
unit will stop, the status bar will change to ELECTRIC and the unit will
restart in Electric Operation.
START/STOP
DIESEL
BOX TEMPERATURE
o
F
SETPOINT
o
F
LANGUAGE
DATA
RECORDER
34
.3 34
STANDBY
START/STOP
ELECTRIC
BOX TEMPERATURE
o
F
SETPOINT
o
F
STANDBY
DIESEL
34
.3 34
EXIT
3
4
Summary of Contents for Vector 8500
Page 1: ...Operator s Manual Vector 8500 Trailer and Rail Refrigeration Units 62 11646 00 Rev D TM ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 57: ......