Start-Stop is provided to reduce fuel or power consumption by allowing full
automatic control of unit shut down and restart by monitoring compartment
temperature, battery charge and, when in Engine operation, coolant
temperature. The main function of Start-Stop operation is to turn off the
refrigeration system near setpoint to provide an efficient temperature control
system and to initiate a restart sequence after certain conditions are met.
1. With the system powered up (START/RUN-OFF switch in the START/RUN
position) press the START-STOP/CONTINUOUS key until the desired
operation (Start/Stop or Continuous) is highlighted.
2. “START/STOP MODE SELECTED” or “CONTINUOUS RUN MODE
SELECTED” will be displayed in the MessageCenter for 10 seconds.
3. The operation indication in the status bar will no longer be highlighted. The
unit is now running in the displayed mode.
NOTE
If “CONTINUOUS LOCKED” or “START/STOP LOCKED” is displayed,
the system is currently locked into the displayed mode of operation and
cannot be changed using the “START/STOP - CONTINUOUS” key.
Whenever the unit starts in Start-Stop, it will run until:
• The selected minimum run time has expired
• The compartment temperature is at setpoint
2
1
START/STOP
DIESEL
COOL
BOX TEMPERATURE
o
F
SETPOINT
o
F
START/STOP MODE SELECTED
34
.3 34