1. With the system powered up (START/RUN-OFF switch in the START/RUN
position) press the ALARM key.
2. If there are active alarms, the alarm number will be displayed preceded by
the letter “A” (active alarm). The system may also be configured to display
an alarm description, following the alarm number. The last alarm that
occurred will be the first alarm displayed and so on.
3. Next to the ACTIVE ALARMS screen name in the status bar, information
on the total number of alarms and the position in the list of the highlighted
alarm is provided. (In the illustration above there are three alarms, the
second alarm is highlighted.)
4. Press the
▲
or
▼
key to scroll through the list of alarms.
5. To clear the alarms, press the CLEAR ALARMS soft key. The display will
provide an “ACTIVE ALARMS CLEARED” message and then return to the
default display after 10 seconds.
6. If there are no active alarms, the display will provide a “NO ACTIVE
ALARMS” message and then return to the default display after five
seconds.
2
5
3
ACTIVE ALARMS (2 OF 3)
A00013 HIGH DISCHARGE PRESSURE
BACK
A00028 CHECK REFRIG SYSTEM
CLEAR
ALARMS
A00022 LOW SUCTION PRESSURE
1
4