45
62-11646
F
USES
- C
ONTINUED
WARNING
!
When replacing fuses, lockout/tagout the power plug and the
negative battery cable.
*With EES installed F8 = 10 amp for FLS and EES
Fuse
Purpose
Amps
Volts
F1
Module Logic Circuit and
Buzzer Power
5A
12VDC
F3
Stepper Valve Module
Component Actuation and
Engine Control Unit Power
5A
12VDC
F5
Power Enable Relay Contact
Power
30A
12VDC
F6
AutoFresh Air Exchange
Solenoid Power
10A
12VDC
F7
Main Power
80A
12VDC
F8*
Fuel Level Sensor Power
5A
12VDC
F9
Contactor Control Board
Component Actuation Power
5A
12VDC
F10
Main Microprocessor Module
Component Actuation Power
20A
12VDC
F11
Light Bar Power
5A
12VDC
F12
Satellite Communications
Power
5A
12VDC
F14
Fuel Heater Power
15A
12VDC
F33, 34, 35
Battery Charger
5A (timed)
600VAC
F36, 37, 38
Condenser and Evaporator
Fan
Motors
12A
600VAC
F39, 40, 41
Coil/Drain Pan Heaters
12A (timed)
600VAC