SECTION 6
MESSAGECENTER MESSAGES
6.1
MESSAGECENTER MESSAGES
The following table lists common messages which do not appear in other lists in this manual and a description of
their meaning. Refer to
for a list of Alarm messages. Refer to
sages. Refer to
for a list of Functional Parameter messages. Refer to
for a list of Con-
figuration messages.
Table 6–1 MessageCenter Messages
Message
Description
ACTIVE
This message will appear in the MessageCenter along with the current
IntelliSet indicating that the IntelliSet is active and none of its settings
have been modified.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the microprocessor has been erased. (This
does not remove alarms from the DataLink data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the microprocessor alarm lists
have been erased. (This does not remove alarms from the DataLink
data recorder.)
BUZZER OFF IN X MINS
The Buzzer circuit has been energized in Component Test Mode. The
Buzzer circuit will continue to be energized for the number of minutes
shown.
CANNOT ENTER TRIP START
Cannot enter Trip Start. A problem has been detected within the Data-
Link data recorder.
CANNOT START DEFROST CYCLE
Due to current unit conditions, the defrost cycle cannot be started.
Refer to Defrost
CANNOT START PRETRIP
Due to current unit conditions a Pretrip test cannot be started. Refer to
Pretrip
CHANGE INTELLISET TO EXIT
The IntelliSleep IntelliSet is active. Alternates with “INTELLI
−
SLEEP
MODE” at 5 second interval whether unit is running or not.
CHARGE MODE
−
HOLD = TO EXIT
Service Mode has the refrigeration system set so that it can be charged
with refrigerant through the liquid line service valve. Press the = key to
manually exit, or wait until the charging is complete.
CHECK AT NEXT SERVICE INTERVAL The unit needs to be checked at next service interval. There is current-
ly an active non
−
shutdown alarm in the alarm list.
CHECK DOOR
The door switch indicates that a refrigerated compartment door is not
closed.
CHECK FUEL LEVEL
(Requires Optional Sensor)
The level in the fuel tank is very close to empty.
COMPONENT TEST MODE
Pressing the = key while this message is highlighted will allow user
access to Component Test Mode.
CONTINUOUS LOCKED
The current setpoint is within a range that has been locked into the
Continuous Run Mode. Start
−
Stop can not be selected.
CONTINUOUS RUN MODE SELECTED The unit operating mode has been changed from Start-Stop to Contin-
uous Run.
DATA RECORDER FAILURE
The microprocessor has stopped recording Unit Data.
DEFROST CYCLE STARTED
The unit has gone into defrost.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......