7–27
62-11640
00041
ENGINE STALLED
• ACTIVATION: The control system is calling for the engine to run, Engine speed sensor is good, and
engine speed is less than 10 rpm;
or
the A00130 (Check Engine RPM Sensor) alarm is ON, and the Oil
Pressure switch contacts are open.
• UNIT CONTROL: Engine Operation: Engine and unit shutdown and alarm.
Electric Operation: This alarm will not activate in Electric Operation.
• RESET CONDITION: Auto Restart after 15 minutes, or Alarm may be manually reset using the display
mounted keys or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check For Additional Alarms
a. If this alarm is activated in conjunction with other alarms (00031, or 05012) check F5 & F10. Verify
correct fuse, check fuse holder for damage, see
. Replace fuse as required. Clear
alarms, restart and check for repeat alarm(s).
b. Check for alarm 00130. When alarms 00130 and 00041 occur at the same time, generally the
engine has run out or is running out of fuel. This causes the engine speed to surge and drop.
Check fuel tank and add fuel as necessary. Check fuel lines between the fuel tank and the fuel
pump inlet for air leakage.
2.
Check Start/Run-Off Switch & Circuit
a. Check SROS. Must be in the START/RUN position.
b. Check two way communication equipment. Must be set to allow operation and calling for operation.
3.
Check Fuel System
a. Check for Alarm 00001 (Low Fuel Level Warning). Fill tank as needed.
b. Check fuel flow. Unrestricted fuel flow through system. Pump screen(s) clean. Fuel not gelled.
c. Check fuel system prime. No air in fuel system.
4.
Check Engine Control Unit (ENCU) and Fuel Speed Actuator (FSA)
a. Check voltage from fuse F3 through PCM
−
34 and SP
−
18 to ENCU
−
22. Verify correct fuse, see
. Must have minimum 11 VDC with the battery connected and SROS in the OFF position.
b. Check voltage from 3MM-9 to ENCU
−
44. Must have minimum 11 VDC with SROS in the START/
RUN position. If not, energize the run relay output using component test mode (refer to
c. Check for ground at ENCU-19 and ENCUGND
−
A (at the battery negative cable connection). If
ground not good, check connectors and wiring between terminals for damage, moisture or corrosion.
d. Inspect fuel/speed actuator (FSA), engine speed sensor (ENSSN) and engine speed control unit
(ENCU) connector pins & terminals. Verify no physical damage to components, and no damage or
corrosion in connectors.
e. Check resistance & amp draw of FSA. Refer to
f. Check FSA plunger. Must move in and out freely. Refer to engine manual.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......