62-11640
7–74
P00206
CHECK CONDENSER FAN CIRCUIT
• ACTIVATION: Normal draw for the CDCON contactor coil is 0.05 to 2.0 Amps (12 VDC). The circuit tests
outside this range.
• UNIT CONTROL: Engine and Electric Operation: Pretrip will fail and display “PRETRIP FAIL AND COM-
PLETED”.
• RESET CONDITION: Auto Reset if Pretrip is started again, or alarm may be manually reset via keypad or
by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check CDCON
a. Inspect CDCON contactor coil and wire connections.Verify there is no damage to coil, and no
damage, moisture, or corrosion in connections.
b. Check contactor coil resistance. Refer to
.
2.
Check CDCON Amp Draw
Check CDCON contactor coil amp draw. Use Component Test Mode (
for amp values. View current draw in Component Test Mode screen.
3.
Check CDCON Wiring
Inspect harness & control box connector pins & terminals. (See wiring schematic
) Ver-
ify there is no physical damage to harness, and no damage, moisture, or corrosion in connectors.
P00207
CHECK COMPRESSOR CONTACT CIRC
• ACTIVATION: Normal draw for the CCON contactor coil is 0.0 to 1.0 Amps (12 VDC). The circuit tests
outside this range.
• UNIT CONTROL: Engine and Electric Operation: Pretrip will fail and display “PRETRIP FAIL AND COM-
PLETED”.
• RESET CONDITION: Auto Reset if Pretrip is started again, or alarm may be manually reset via keypad or
by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check CCON
a. Inspect CCON contactor coils and wire connections. Verify there is no damage to coil, and no
damage, moisture, or corrosion in connections.
b. Check contactor coil resistance Refer to
2.
Check CCON Amp Draw
a. Check CCON contactor coil amp draw. Use Component Test Mode (
to
for correct electrical values. View current draw in Component Test Mode screen.
b. Listen for CCON to pull in. If CCON contactor pulls in, CCON is OK. If CCON contactor does not
pull in, check for 12 VDC at CCON coil. 12 VDC indicates defective CCON coil.
3.
Check CCON Wiring
Inspect harness & control box connector pins & terminals. (See wiring schematic
) Ver-
ify there is no physical damage to harness, and no damage, moisture, or corrosion in connectors.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......