62-11640
1–4
WARNING
!
Do not direct water or steam into the gen-
erator openings. Do not allow any soap
and water solutions to enter the generator.
WARNING
!
Generators of this type should not be
“flashed.” Operation with external voltage
source or momentary shorting of leads
will damage the generator and may cause
injury.
WARNING
!
A mica shim (Carrier Transicold part
number 54
−
00630
−
25) must be installed
before removal of the generator. The gen-
erator is to be removed as one piece, with
the shim in place. DO NOT attempt to
remove the rotor from the stator.
WARNING
!
Never disassemble the generator rotor
from the stator due to the high force
required to do so and the high magnetic
field that will result. The field present
when the rotor is disassembled from the
stator may interfere with cardiac implants
such as pacemakers and defibrillators.
CAUTION
!
Service Mode MUST be used whenever
removing refrigerant charge, refrigerant
leak checking or evacuating.
CAUTION
!
Before connecting a megohmmeter,
place the Main Power switch in the OFF
position. Disconnect the high voltage
source, lockout/ tagout the receptacle
and disconnect the negative battery con-
nection. Isolate the microprocessor by
disconnecting all connectors and wires
going to it. Observe National Electric
Manufacturer’s Association (NEMA) rules
and test equipment manufacturers
instructions.
NOTICE
Electronic modules MUST be handled
with care to prevent accidental damage
or degradation from electrostatic dis-
charge (ESD), contamination or abuse.
Before touching a module, touch your
body and/or conductive tool being used
to the frame to discharge ESD safely. All
electronics should be handled carefully
and only held by edges of any exposed
board. Care should be taken when insert-
ing/extracting connectors and compo-
nents to avoid exerting excessive stress
on the board which could fracture small
components nearby, resulting in future
failure of circuit.
NOTICE
Under no circumstances should a techni-
cian electrically probe the modules at any
point, other than the connector terminals
where the harness attaches. Module com-
ponents operate at different voltage lev-
els and at extremely low current levels.
Improper use of voltmeters, jumper
wires, continuity testers, etc. could per-
manently damage the module.
NOTICE
Use Texaco Havoline extended life cool-
ant or any other extended life coolant
which is Dexcool approved and has 5/150
(5 years / 150,000 miles) on the label.
NOTICE
Technician Mode should be canceled
when work is complete. If Technician
Mode is not canceled, Technician Mode
will be available for 60 minutes after the
last key press without requiring a code,
even after placing the SROS in the OFF
and then back in the RUN/ STOP position.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......