CONFIGURATIONS ERROR
• ACTIVATION: There is an error in the Configuration settings that are stored in the main microprocessor
memory.
• UNIT CONTROL: Engine and Electric Operation: Incorrect Configuration(s) will be automatically set for
default value.
• RESET CONDITION: Auto reset when valid Configuration(s) are entered, or alarm may be manually
reset by turning the unit off, then back on again
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (refer to reset condition above). Operate the unit through the appropriate modes to see
if any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Configurations
Check Configurations. All must be set for selectable values.
2.
Check Software Version
Check microprocessor software version. Upgrade to the latest version of software. If changes were
made using a newer version of TRU
−
Tech, that version may contain Configurations that were not
present in older versions of control system software.
3.
Reconfigure Microprocessor
Send settings to microprocessor. Using the latest version of TRU-Tech and a Data Transfer USB
Memory Device, write the desired Configuration file to the device, then load the file into the micropro-
cessor. Allow the microprocessor to reboot itself.
4.
Reset Microprocessor
a. Place the START/RUN-OFF switch in the OFF position. Disconnect positive battery cable, remove
F7 fuse or unplug 1MM connector, wait 20 seconds and reinstall. Then place the START/RUN-
OFF back in the START/RUN position. The microprocessor powers up OK and the latest setpoint
appears in the display.
b. Check for valid Configuration settings in Configuration List. Values are set correctly for all parame-
ters. Alarm is cleared.
c. Disconnect positive battery cable from the battery, wait 30 seconds, then reconnect and place the
START/RUN-OFF switch in the START/RUN The microprocessor powers up OK and the latest
setpoint appears in the display.
d. Check for valid Configuration settings in Configuration List. Values are set correctly for all parame-
ters. Alarm is cleared.
e. Valid Configurations can not be entered and alarm remains active. Download data and replace the
main microprocessor module (MM). Refer to
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......