7–109
62-11640
23100
NO COMM FROM MICRO TO OUTPBD1
• ACTIVATION: Main microprocessor cannot communicate internally.
• UNIT CONTROL: Engine and Electric Operation: Shutdown all modules except the display and alarm.
(The alarm will only display if the display module is communicating.) Main microprocessor status LED will
illuminate steady green (not pulsing).
• RESET CONDITION: Auto reset when internal communication is restored, alarm reset or alarm may be
manually reset by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Replace Main Microprocessor
Download data and replace main microprocessor. For complete Main Microprocessor Module
replacement instructions refer to
23101
OUTPUT LOST CONFIGURATION
• ACTIVATION: Output Board reports an invalid configuration.
• UNIT CONTROL: Engine and Electric Operation: Required Shutdown.
• RESET CONDITION: Auto reset when communication is restored, or alarm may be manually reset by
turning the unit off, then back on again.
CORRECTIVE ACTIONS:
1.
Check Wiring
Check logic power connections. Check wiring at 1MM6 & 1MM1.
2.
Replace Main Microprocessor
Download data and replace main microprocessor. For complete Main Microprocessor Module
replacement instructions refer to
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......