62-11640
3–22
3.15 VIEW ACTIVE ALARMS
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode press
the ALARM key.
2. If there are active alarms, the alarm number will be displayed preceded by the letter “A” (active alarm). The
last alarm that occurred will be the first alarm displayed.
• If the alarm list is viewed when in the Driver Mode, the alarm descriptions will only display if the System is
configured to do so.
• When viewing the alarm list in the Advanced User Mode or Technician Mode the alarm description will
display, following the alarm number.
• Next to the ACTIVE ALARMS screen name in the status bar, information on the total number of alarms
and the position in the list of the highlighted alarm is provided. (In the preceding illustration there are 5
alarms and the second alarm is highlighted.)
3. Press the
▲
or
▼
key to scroll through the list of alarms.
4. To clear the alarms, press the CLEAR ALARMS soft key. The LCD Display will provide an “ACTIVE
ALARMS CLEARED” message to confirm the alarms have cleared.
5. If there are no active alarms, the LCD Display will provide a “NO ACTIVE ALARMS” message and then
return to the default display after 5 seconds.
Alarms are stored in the Alarm List in the main microprocessor. Stored alarms may be viewed in the
Message-Center. For a complete list of alarms, their meanings, and troubleshooting refer to
.
TIP
Another way to clear active alarms is to turn the control system OFF and then back on using the
START/RUN - OFF switch.
TIP
The inactive alarm list may only be viewed while in Technician Mode, refer to
. Only
qualified refrigeration technicians should access the inactive alarm list. It is not intended for the use of
Drivers or Advanced Users.
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
ACTIVE ALARMS (2 of 5)
CLEAR
ALARMS
BACK
A00013 High Discharge Pressure
A00022 Low Suction Superheat
A00028 Check Refrig System
2
1
4
3
3
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......