3–29
62-11640
Pressing the = key will allow the user to select the date
and time the unit is to automatically wake up. The wake
up time must be at least 1 hour and no more than 8
days from the time the clock is set. The following infor-
mation can be entered:
• Month (1 to 12).
• Day (1 to 31).
• Year (2009 to 2099).
• Hour (0 to 23).
• Minute (0 to 59).
NOTE
The system uses a 24 hour clock. Hours 00
to 11 are AM and hours 12 to 23 are PM.
2. “RUN PRETRIP TEST AT WAKE” may be set to
YES or NO, the default setting is NO.
a. When “PRETRIP TEST AT WAKE” is set to NO
the unit will wake up at the designated time and
control to setpoint.
b. When “PRETRIP TEST AT WAKE” is set to
YES. the unit will wake up at the designated
time, automatically run Pretrip and then control
to setpoint. “PRETRIP PASS/FAIL” will remain in
the Message- Center until it is manually cleared
by pressing any key.
If Sleep Mode is selected, when the unit is not running
during a Start-Stop Off Cycle, any remaining Minimum
Off Time will be ignored, and the engine will start. It will
run for 4 minutes (minimum), until the engine coolant
temperature is above 95°F (35°C), the battery is
charged (“OK” is displayed in the battery unit data
reading) and charging amps are less than the config-
ured setting. When the unit is running while in Sleep
Mode, “SLEEP WARNING: NO TEMP CONTROL” will
flash in the MessageCenter.
If the unit is already running when Sleep Mode is
selected, it will continue to run until the conditions
described above are met.
While the unit is cycled off in Sleep Mode, “SLEEP
MODE, OFF/ON TO WAKE” will be displayed in the
MessageCenter. The display backlight will turn off after
5 minutes.
While in Sleep Mode, Unit Data and Alarm Lists may
be viewed, and Functional Parameters may be viewed
and changed as necessary. However, Start-Stop/Con-
tinuous Run selections and setpoint can not be
changed. Manual Defrost and Pretrip can be initiated.
The unit will restart when engine coolant temperature
drops below the configured restart temperature value
or if the battery voltage drops below the configured bat-
tery restart value.
NOTE
In the event that the Engine Coolant Tem-
perature sensor fails, Sleep Mode will oper-
ate as follows:
In ambients above 32°F (0°C), the unit will
run as above, and will monitor battery volt-
age and charging amps only (according to
the Configuration setting).
In ambients below 32°F (0°C), the unit will
run for 20 minutes minimum run time, then
restart every 60 minutes (maximum off time).
Battery voltage and amperage will be moni-
tored normally.
Summary of Contents for Vector 8500
Page 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Page 24: ...1 7 62 11640 62 03958 ...
Page 25: ...62 11640 1 8 ...
Page 26: ...1 9 62 11640 ...
Page 27: ...62 11640 1 10 ...
Page 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 321: ......
Page 322: ......