Technician Hour Meters
Hour meters, other than standard hour meters are available for viewing when in Technician Mode. Instructions for
viewing these hour meters are provided in
Figure 5.2 Technician Hour Meters
1. Enter the Technician Mode, as described in
. While in the TECHNICIANS MENU screen, press
the BACK or EXIT key and then press the MENU key until HOUR METERS is displayed.
2. Press the HOUR METER soft key to display the hour meter screen.
3. The hour meter screen will display with a 15 second timeout. Press the
▲
or
▼
key to scroll through the
available selections. With the desired sub-menu highlighted, press the “=” key to view the data.
4. The number of meters displayed depends on the settings for this unit. Press the BACK key to return to the
HOUR METERS screen or the EXIT key to return to the default screen. Once activity requiring use of Tech-
nician Mode is complete, Technician Mode should be manually canceled, refer to
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
1
2
BACK
EXIT
Standard Hour Meters
Other Meters & Counters
Maintenance Hour Meters
Reset PM Hour Meters
HOUR METERS
END OF LIST
(1 OF 4)
Note: This line will only display if
one or more meters has timed
out and is ready to be reset.
STANDARD HOUR METERS
BACK
EXIT
Engine Hours
Switch On Hours
Standby Hours
Total Run Hours
1060 Hours
1400 Hours
123 Hours
1182 Hours
END OF LIST
MAINTENANCE METERS
BACK
EXIT
Time Left to (Meter Name) #####
END OF LIST
OTHER METERS & COUNTERS
BACK
EXIT
Meter/Counter List
END OF LIST
Standby Protect Hours
Engine Protect Hours
Switch On Protect Hours
Engine Sleep Hours
Switch On Sleep Hours
High Speed Hours
Compressor Hours
Start Cycles
High Speed Hours
Standby Hours
Start Cycles
Switch On Hours
Engine Hours
Compressor Hours
As Configured
Number of Hours
or Cycles.
RESET PM HOUR METERS (1 OF 2)
BACK
EXIT
END OF LIST
RESET
Time Left to Engine Hours 0
Time left to Switch On Hours 0
To reset an hour meter, highlight it and then press
the RESET soft key. In this example, the Switch On
meter would be reset.
Summary of Contents for Vector 8500